Operation
Before Startup
Illustrations on Page 3
Illustration ![]()
ÎPull out the clamp for the
Illustration ![]()
ÎConnect high pressure hose to trigger gun.
ÎPush the clamp in until it locks. Check the secure connection by pulling on the
Water supply
According to the applicable regula- tions, the appliance must never be used on the drinking water supply ![]()
![]()
![]()
without a system separator. Use a suitable system separator manufactured by KÄRCHER; or, as an alternative, a system separator as per EN 12729 Type BA. Water flowing through a system separator is con- sidered
Caution
Always connect the system separator to the water supply, never directly to the appli- ance!
Note: Impurities in the water can damage the
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/tech- nical data.
ÎUse a
ÎScrew the coupling element (supplied) to the water connection on the appli- ance.
ÎPush the water supply hose onto the coupling unit, then connect it to the wa- ter supply.
How to draw water from a bucket when using a KÄRCHER Pressure Cleaner KÄRCHER recommends using the suction hose accessory (sold separately) Order no.
STEP 1:
ÎConnect the suction hose to the water inlet on the pressure cleaner and drop the other end into a bucket.
Tip: If you are not using this accessory, coil a hose into the bucket and ensure that you only use a standard hose clamp to connect to the pressure washer.
CLICK FITTINGS MUST NOT BE USED!
STEP 2:
ÎFill up your bucket with water.
STEP 3:
ÎConnect the KÄRCHER power cord to an electricity source and turn on at pow- erpoint. Make sure the high pressure nozzle is not connected and turn the unit on at the ON/OFF switch. Press the trigger on the gun - the unit is ready for use once there is a constant water sys- tem.
6English