Symptom

Cause

Solution

No detergent.

Detergent suction tube not

Check connection.

 

properly connected to the ma-

 

 

chine.

 

 

Detergent is too thick.

Dilute detergent, for best re-

 

 

sults use Kärcher detergent.

 

Filter on detergent suction

Run warm water through filter

 

tube is clogged.

to remove debris.

 

Damaged or clogged deter-

Remove obstruction or re-

 

gent suction tube.

place detergent suction tube.

 

Spray wand is in high pres-

Turn spray wand tip to low

 

sure position.

pressure position.

 

Discharge nozzle is obstruct-

Blow out or remove debris

 

ed.

with fine needle.

Garden hose con-

Loose fittings.

Tighten fittings.

nection leaks.

Missing/worn rubber washer.

Insert new washer.

Spray wand leaks.

Spray wand not properly at-

Insert the spray wand into the

 

tached.

trigger gun. Carefully press in

 

 

against the spring tension

 

 

and twist into the locked

 

 

position.

 

Broken o-ring or plastic insert.

Call Customer Support

Pump is noisy.

Pump is sucking air.

Check that hoses and fittings

 

 

are air tight. Turn off machine

 

 

and purge pump by squeez-

 

 

ing trigger gun until a steady

 

 

flow of water emerges

 

 

through the nozzle.

Water leaks from

Loose fittings.

Check that all fittings are

pump (up to 10 drops

 

tight.

per minute is permis-

Water seals are damaged or

Call Customer Support

sible).

worn.

 

Oil Drip.

Oil seals are damaged or

Call Customer Support

 

worn.

 

Kärcher Customer Support USA

 

Kärcher Customer Service CDN

If you encounter any additional difficul-

 

Call: 1-800-465-4980for help or visit

ties not listed, please call

our website: www.karcher.ca

1-800-537-4129for help or visit our

 

Kärcher Customer Support Mexico

website: www.karcher-usa.com/home

 

 

Call: 01-800-024-13-13for help or visit

 

 

our website: www.karcher.com.mx

16English

Page 16
Image 16
Karcher K 2.19 manual Symptom Cause Solution