Before Startup

Before Startup

Mount loose parts delivered with appliance prior to start-up.

Illustrations on Page 5

ÎIllustration Water supply

Insert the transport handle.

ÎIllustration Water supply from mains

Insert the transport wheels and lock them.

ÎIllustration Start up

Pull out the clamp for the high-pressure hose from the trigger gun (e.g. a small screwdriver).

ÎIllustration Operation

Connect high pressure hose to trigger gun.

Push the clamp in until it locks. Check the secure connection by pulling on the high-pressure hose.

Water supply

According to the applicable regula- tions, the appliance must never be used on the drinking water supply Trigger gun with EPC–Step 3 - Maximum:–Step 2 - Medium:–Step 1 - Soft: without a system separator. Use a suitable system separator manufactured by KÄRCHER; or, as an alternative, a system separator as per EN 12729 Type BA. Water flowing through a system separator is con- sidered non-drinkable.

Note: Impurities in the water can damage the high-pressure pump and accessories. For protection, the use of the KÄRCHER water filter (optional accessory, order no. 4.730-059) is recommended.

Water supply from mains

Observe regulations of water supplier.

For connection values, see type plate/tech- nical data.

ÎUse a fibre-reinforced water hose (not included) with a standard coupling. (Minimum diameter 1/2 inch (13 mm), minimum length 7.5 m).

ÎScrew the coupling element (supplied) to the water connection on the appliance.

ÎPush the water supply hose onto the coupling unit, then connect it to the wa- ter supply.

6English

Start up

Caution

Dry runs lasting longer than two minutes lead to damages to the high pressure pump. If the appliance does not build up pressure within two minutes, switch it off and proceed as instructed in the Chapter "Help with faults".

ÎConnect the high pressure hose to the high pressure connection of the appli- ance.

ÎPush the spray lance into the trigger gun and fasten it by turning it through 90°.

ÎCompletely open the water tap.

ÎInsert the mains plug into the socket.

ÎTurn on the appliance “I/ON”.

Operation

￿Danger

The trigger gun is subjected to a recoil force when the water jet is discharged. Make sure that you have a firm footing and are also holding the trigger gun and spray lance firmly.

ÎUnlock the lever on the trigger gun.

ÎPull on the lever of the trigger gun; the

device will switch on.

Note: Release the lever of the trigger gun; the device will switch off again. High pres- sure remains in the system.

Trigger gun with EPC

EPC: 3-Step electronic power control.

ÎLoose lever on the trigger gun briefly (less than one second) to change EPC- setting.

The EPC power steps will be changed

one after another, from Step 3, over Step 2, to Step 1. From Step 1 it will be changed back to Step 3.

Step 3 - Maximum:

Maximum pressure and water flow.

Step 2 - Medium:

Reduced pressure and water flow.

Step 1 - Soft:

Gentle pressure and water flow.