Karcher K 2.56 M manual Servicing Of A Double Insulated Product, WATER SUPPLY Cold Water Only

Models: K 2.56 M

1 48
Download 48 pages 48.21 Kb
Page 5
Image 5
SAVE THESE INSTRUCTIONS

TO SPRAY GUNS, HOSE AND HOSE CONNECTIONS).

„BEFORE SERVICING, CLEANING OR REMOVING ANY PARTS, SHUT OFF POWER AND RELIEVE PRESSURE.

„IF CONNECTION IS MADE TO A POTABLE WATER SYSTEM, THE SYSTEM SHALL BE PROTECTED AGAINST BACKFLOW.

SAVE THESE INSTRUCTIONS

SERVICING OF A DOUBLE-

INSULATED PRODUCT

In a double-insulated product, two sy- stems of insulation are provided instead of grounding. No grounding means is provided on a double-insulated product, nor should a means for grounding be added to the product. Servicing a doub- le-insulated product requires extreme care and knowledge of the system, and should be done only by qualified service personnel. Replacement parts for a double-insulated product must be iden- tical to the parts they replace. A dou- bleinsulated product is marked with the words “DOUBLE INSULATION” or “DOUBLE INSULATED”. The symbol “ SERVICING OF A DOUBLE-” may also be marked on the product.

GROUND FAULT CIRCUIT INTER-

RUPTER PROTECTION

This pressure washer is provided with a ground-fault circuit-interrupter (GFCI) built into the plug of the power-supply cord. This device provides additional protection from the risk of electric shock. Should replacement of the plug or cord become necessary, use only identical replacement parts that include GFCI protection.

WATER SUPPLY (Cold Water Only)

￿CAUTION

When connecting the water inlet to the water supply mains, local regulations of your water company must be observed. In some areas the unit must not be con- nected directly to the public drinking wa- ter supply. This is to ensure that there is no feedback of chemicals into the water supply. Direct connection via a receiver tank or backflow preventer, for example, is permitted.

Dirt in the feed water will damage the unit. To avoid this risk, we recommend fitting a water filter.

„Garden hose must be at least 5/8 inch in diameter.

„Flow rate of water supply must not fall below 2 GPM (gallons per minute).

„Flow rate can be determined by run- ning the water for one minute into an empty 5-gallon container.

„The water supply temperature must not exceed 104°F/40°C.

„Never use the pressure washer to draw in water contaminated with sol- vents, e.g. paint thinners, gasoline, oil, etc.

„Always prevent debris from being drawn into the unit by using a clean water source.

English 5

Page 5
Image 5
Karcher K 2.56 M manual Servicing Of A Double Insulated Product, Ground Fault Circuit Inter Rupter Protection