Install the high pressure hose drum
Illustration
Slide the free end of the coiled high pressure hose through the recesses on the dosage regulator.
Insert the hose drum into the intakes on the transport handle.
Insert the axle of the hand crank into the guides.
Install the fixating plate and secure it using 2 screws.
Press the connecting fitting from the short high pressure hose into the brass intake, secure with clamps.
Note: Make sure the connection nipple is aligned correctly.
Connect the high pressure hose to the hand spray gun
Illustration
Push the high pressure hose into the trigger gun until it locks audibly.
Note: Make sure the connection nipple is aligned correctly.
Check the secure connection by pulling on the high pressure hose.
Water supply
Warning
According to the applicable regula- tions, the appliance must never be used on the drinking water supply without a system separator. Use a suitable system separator manufactured by KÄRCHER; or, as an alternative, a system separator as per EN 12729 Type BA. Water flowing through a system separator is con- sidered
Caution
Always connect the system separator to the water supply, never directly to the appli- ance!
Note: Impurities in the water can damage the
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/tech- nical data.
Use a
Illustration
Screw the supplied coupling element to the water connection on the appliance. Push the water supply hose onto the coupling unit, then connect it to the wa- ter supply.
How to draw water from a bucket when using a KÄRCHER Pressure Cleaner
KÄRCHER recommends using the suction hose accessory (sold separately) Order no.
STEP 1:
Connect the suction hose to the water inlet on the pressure cleaner and drop the other end into a bucket.
Tip: If you are not using this accessory, coil a hose into the bucket and ensure that you only use a standard hose clamp to connect to the pressure washer.
CLICK FITTINGS MUST NOT BE USED!
STEP 2:
Fill up your bucket with water.
– 10 |