Karcher NT 611, NT 361 manual Operating Instructions, English, Dry suction Manual mode

Models: NT 611 NT 361

1 14
Download 14 pages 1.58 Kb
Page 5
Image 5
Operating Instructions

Operating Instructions

NT 361 Eco TEA / NT 611 Eco TEA

English

Dry suction

Manual mode

English Warning!

During vacuuming it is not permitted to ever remove the flat pleated filter.

A paper filter bag or a diaphragm filter (special accessories) can additionally be used to vacuum fine dust.

Fitting the paper filter bag

!Unlock and remove the suction head

!Attach the paper filter bag

!Replace the suction head and lock it in place

!Insert power plug

!Switch unit to manual operation (1)

!Turn on unit (2) and start operating it

Automatic operation with a pneumatic and/or a power tool

!Switch unit to automatic operation (2)

!Plug power tool’s power plug into vacuum cleaner (3) or connect pneumatic tool (4) and open compressed air supply

!Switch on the machine (1)

Note:

The vacuum cleaner is automatically started and stopped when the power toool is turned on and off.

The vacuum cleaner has a starter delay of up to 0,5 s and an after-running time of

up to 15 s.

See page – technical data - for connected performance data of the tools.

Adapt connecting sleeve to tool adaptor.

!Remove the pipe bend from the suction hose

!Install the connection sleeve to the suction hose