House connection amplifier

VOS 32/F

 

20910020

House connection amplifier

House connection amplifier for modern HFC networks Built-in power supply

Die-cast housing with F-type connectors LED to indicate operation mode

Gain with interstage attenuation is switchable using jumpers (delivery condition: high gain)

The maximum operation levels are also valid for operation with interstage attenuation

Interstage equaliser (6 dB) can be connected using jumpers (max. operation level increases by 2 dB)

Optional return path, can be equipped individually:

5-30 MHz with VGR 28/30; 5-65 MHz with VGR 28/65 (Delivery status: without return path amplifier, with jumper) Built-in variable attenuator and variable equaliser

Test socket on output -20 dB (with directional coupler)

Test socket on input -20 dB (can be connected with jumper) for levelling of return path

Complies with: EN 60728-11, EN 50083-2 and EN 60065 For indoor installation

The amplifier complies with the requirements in the EMC Directive 2004/108/EC and Low-Voltage Directive 2006/95/EC applica- ble at the time of shipping

Dimensions and Installation

Only by authorised personnel

Unplug from the mains before installation. The safety regulations in accordance with EN 60728-11 and EN 60065 are to be observed!

House connection amplifier

InputOutput

 

F-type socket 4x

 

 

Potential equalisation

Connection dimensions acc.

 

Clamping range 4...6 mm2

to IEC 61169-24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mains power cable (L= approx. 1m)

Permissible installation

Caution!

Do not install on flammable materials!

a

b

House connection amplifierb

 

 

 

Input

Output

 

 

 

 

 

a

a)Clearances to containing surfaces: ≥ 150 mm

b)Clearances to containing surfaces: ≥ 50 mm

936.3291/-/0208/5.8e