Kaz 4220 How Your Humidifier Works, Read and Save These Instructions, Care and Cleaning, Model

Models: 4100 4220 4200

1 2
Download 2 pages 18.7 Kb
Page 2
Image 2
How Your Humidifier Works

How Your Humidifier Works

MODEL 4100

Read and Save These Instructions

1. CAUTION: UNRAVEL CORD BEFORE USE. Failure to do so could cause overheating and possible fire

hazard.

DAILY MAINTENANCE

1. Model 4100: Unplug cord from electrical outlet.

Models 4200 and 4220: Turn the switch to the Off (O) position and unplug the cord from electrical outlet.

2. Remove Top Housing and place upside down on a flat surface. For model 4100, use lift tabs

TOP HOUSING

WATER FILLCHANNEL™

DYNAFILTER® K14

AIR-CLEANING FILTER

OUTPUT GRILLE

Always disconnect cord at wall plug before removing the Top Housing or when humidifier is not in use.

2. INSERT DYNAFILTER CARTRIDGE. Simply remove the outer protective wrap and insert the DynaFilter cartridge into the recess of the Top Housing (WHITE FILTER OUT).

Inspect used DynaFilters. If you notice heavy dirt accumulation, it’s time to replace the DynaFilter.

on both sides of Top Housing to remove. Do not set down on the Pickup Tube. Rinse Base, wipe clean, and dry with a clean cloth or paper towel.

3. Wipe exterior surfaces of the Top Housing with a soft, dry cloth. CAUTION: DO NOT USE WATER TO CLEAN THE TOP HOUSING. ELECTRIC SHOCK MAY RESULT OR HUMIDIFIER MAY BE DAMAGED. DO NOT IMMERSE TOP HOUSING IN WATER.

WATER LEVEL INDICATOR

BASE

3. PLACE HUMIDIFIER IN A SAFE POSITION on floor, table or other FIRM, FLAT and LEVEL surface. Protect rug, floor or furniture by placing unit on a waterproof non-conducting pad or mat for pro- tection against inadvertent spillage. Do not place any object over the humidifier; it could block air openings.

4. Replace Top Housing. Humidifier is now ready for use.

WEEKLY MAINTENANCE

Removing Scale

1. Model 4100: Unplug cord from electrical outlet.

OFF ON

 

MODELS 4200 AND 4220

WATER FILLCHANNEL™

ON-OFF SWITCH

 

 

(2-SPEED SWITCH

 

ON 4220)

TOP HOUSING

DYNAFILTER® K14

 

AIR-CLEANING FILTER

Cord should be out-of-the-way, where it cannot be pulled or stepped on.

When used therapeutically, the humidifier should be placed at least 4 feet from bedside and out of the reach of children.

4. FILL CAREFULLY. The exclusive Kaz FillChannelpermits convenient filling without removing the Top Housing.

Model 4100: Pour cool tap water into FillChannel. Fill until water level reaches Water Level Indicator on the front of bowl.

Models 4200 and 4220: Look down into the FillChannel. You will see the FILL TO HERE marking

Models 4200 and 4220: Turn the switch to the Off (O) position and unplug the cord from electrical outlet.

2. Remove Top Housing and place upside down on a flat surface. Do not set down on the Pickup Tube.

3. Empty any remaining water from Base.

4. Carefully loosen the Pickup Tube from the housing by holding the Disk and rotating the Pickup Tube counterclockwise in the direction of the “OFF” arrow located at the base of the Pickup Tube.

Figure A

BASE

OUTPUT GRILLE

The Kaz HealthMist® 4100, 4200 and 4220 models produce a cool mist through revolutionary new cyclone technology. The motor-driven impeller draws up water through a pickup tube. Centrifugal force throws the water through a screen into the vortex chamber, breaking up the water into a superfine, cool mist.

Each of these cool mist humidifiers restores healthy humidity levels to dry indoor air more effi- ciently than other impeller-type humidifiers.

THE AIR-CLEANING DynaFilter®

Kaz cool mist humidifiers include the exclusive Kaz DynaFilter K14. The DynaFilter removes dust, pollen, odors and tobacco smoke from the air,

removing 93% of particles as small as pollen.

on lower step. Using a pitcher, add cool tap water. Fill only to this mark.

IMPORTANT: DO NOT OVERFILL, as this will cause water spillage and possible damage to floors or furniture.

5. PLUG IN HUMIDIFIER. Be sure that switch is in the Off () position (Models 4200 and 4220 only). Plug power cord into wall.

CAUTION: DO NOT PLUG IN THE CORD WITH WET HANDS; ELECTRIC SHOCK COULD RESULT.

This product has a polarized plug (one blade is wider than the other) as a safety feature. The plug will fit into a polarized outlet only one way. If the plug does not fit properly into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.

6. FOR MODEL 4200: Turn switch to the On (I) position.

FOR MODEL 4220: Turn switch to either of the two speeds - Low (I) or High (II).

CAUTION: Turn off the humidifier if moisture condenses on cold surfaces or walls. Room air may be excessively humid.

7. DIRECTING MIST (Models 4200 and 4220 only) Rotate Output Grille or turn product to prevent mist from settling on tables or other pieces of furniture.

IMPORTANT: To maintain proper operation of your humidifier, be sure to follow Care and Cleaning instructions.

Care and Cleaning

5. Soak Pickup Tube in undiluted white vinegar. Let stand for 20 minutes.

6. Dampen a soft, clean cloth or sponge with undiluted white vinegar and wipe out Base, Pickup Tube and walls around the Pickup Tube.

CAUTION: DO NOT use soap, detergents or abrasive cleaners.

7. Rinse Pickup Tube and Base thoroughly in clean, warm water until scale particles are removed.

8. Wipe exterior surfaces of the Top Housing with a soft, dry cloth. DO NOT IMMERSE OR SPRAY WATER ON THE TOP HOUSING. You are now ready to disinfect the base.

Disinfecting the Base

1. Fill Base with one teaspoon of household bleach in 1 gallon of water. Place the Pickup Tube in the Base and let remain for 20 minutes. Stir every few minutes to insure that all

surfaces are coated.

2. Empty Base after 20 minutes. Thoroughly rinse the Base and Pickup Tube

with water until bleach smell is gone. Dry with clean cloth or paper towel.

3. Wipe all exterior surfaces of the Top Housing with a soft, dry cloth. BE CAREFUL NOT TO IMMERSE OR SPRAY WATER ON THE TOP HOUSING.

ELECTRIC SHOCK MAY RESULT OR HUMIDIFIER MAY BE DAMAGED.

4. Carefully re-attach Pickup Tube by inserting the prongs into the slots in the Disk. While holding the Disk steady, rotate the Pickup Tube clockwise in the direction of the “ON” arrow located at the base of the Pickup Tube.

5. Replace Top Housing on Base. Humidifier is now ready for use.

Under normal environmental conditions, the filter cartridge should be replaced every two months. Replacement time will vary depending upon

END OF SEASON MAINTENANCE

Figure B

the concentration of pollutants in the air. If you notice heavy dirt accumulation on the filter or if the humidifier output is significantly reduced, it’s time to change to a new DynaFilter!

Kaz DynaFilter K14 cartridges are available at leading pharmacies and drug departments. You may also order directly from Kaz (see Order Information on back page).

Tap water may contain pollutants and minerals (scale) that can deposit on the inner surfaces of the humidifier. Such scale can accelerate the growth of microorganisms and it is important that period- ic cleaning is performed as outlined below. More frequent cleaning may be necessary if you notice a heavy build-up of scale.

INSPECT THE DYNAFILTER

Remove and inspect the DynaFilter cartridge for dirt and dust accumulation. If you notice heavy accu- mulation, the filter needs to be replaced. If filter is not changed regularly, dust and other pollutants will clog the filter, impair air flow, reduce the efficiency of the humidifier and may damage the motor.

OR WHEN HUMIDIFIER WILL NOT BE IN USE FOR AT LEAST ONE WEEK

1. Clean and dry the humidifier thoroughly as per the Weekly Maintenance instructions above.

2. Store in a cool, dry location. DO NOT STORE WITH WATER INSIDE THE BASE.

Page 2
Image 2
Kaz 4220, 4200 How Your Humidifier Works, Read and Save These Instructions, Care and Cleaning, Model, Daily Maintenance