20 AA GAS
20 AA GAS
INSTANT RECOVERY® FRYER
DESCRIPTION
The Keating Instant Recovery® 20 AA Fryer consists of a frying vessel 20" sq., having a splash deck and a splash back installed in a cabinet equipped with gas burners and an automatic temperature control mechanism, all arranged and designed for the proper frying of food.
SPECIFICATIONS
Frying Vessel: shall be constructed from 18 gauge stainless steel, shall have a shortening capacity of 100 pounds, shall be equipped with four 18 gauge horizontal heat transfer tubes spaced above the bottom of the vessel so that the bottom is unheated and the food particles collecting in this bottom zone are unheated and therefore do not carbonize. The frying vessel shall be polished to inhibit carbon
Splashdeck shall slope toward the shortening containing vessel. The splash deck shall be made of 16 gauge 304 stainless steel.
Splashback shall be made of 18 gauge 304 stainless steel, shall completely cover the sides of the flue.
Cabinet: shall be made of 18 gauge stainless steel. The cabinet shall be rigid in construction and shall have four 8" adjustable legs. A door made of 22 gauge 304 stainless steel shall cover the front of the cabinet and shall extend from the bottom of the fryer to the panel, and above
the panel shall be a canopy. The door shall be the full width of the cabinet. No additional space is required for the door to open a full 90 degrees. A stainless steel flue deflector is to be provided for installing onto flue back.
Heat Transfer Tubes to be four, made of stainless steel polished to a #7 mirror finish.
Thermostat shall be close range, hydraulic type and be accurate to ±3°F from 300° to 350°F with stainless steel bulb. Application of this thermostat is patented by Keating.
100% Safety Shut Off shall be millivolt type with combination control gas valve and thermopile.
Standard Accessories to include one pair 4 mesh baskets, grid screen over heat transfer tubes, drain clean out rod and sample of Keating Klenzer and Sea Powder.
Electrical Requirements are not necessary on AA models.
Gas Requirements to install are 3/4" male NPT connection and 4" water column pressures natural and 10" for LP gas at the fryer burner manifold. Supply pressure to fryers must be 7" (natural gas) and 11” (LP) water column.
Special Order Options may include battery, common manifold, rear drain, casters, covers, full or triple size baskets, thermostat seals, portable filter, central filter (CF20SE or above), Safe & Easy® filter.
|
| Oil | BTU |
|
|
| Ship | |
Model No. and Description | Capacity | Input | Height | Depth | Width | Wt. | ||
|
|
|
|
|
|
|
|
|
20 | AA Nat Gas | 100 lbs. | 134,000 | 46 1/2" | 34 1/2" | 21 3/8" | 230 lbs. | |
|
|
|
|
|
|
|
|
|
20 | AA LP Gas | 100 lbs. | 132,000 | 46 1/2" | 34 1/2" | 21 3/8" | 230 lbs. | |
|
|
|
|
|
|
|
|
|
20 | Safe & Easy | - | - | 46 1/2" | 38 5/8" | 21 3/8" | - |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| KEATING OF CHICAGO, INC. |
| Toll Free |
| |
As continuous product improvement occurs, specifications may be changed without notice. | www.keatingofchicago.com |
|
|
Printed in U.S.A. | 20AA2007 | 7/07 |