Bypass
Valve
Inlet
Valve
Outlet
Valve
A
B
C
DE
F
FOR SERVICE
close bypass valve
open inlet & outletvalves
FOR BYPASS
open bypass valve
close inlet& outletvalves
%\SDVV YDOYHV VKRXOG DOZD\V UHPDLQ LQ V RIW
ZDWHU VHUYLFH SRVLWLRQ 3RVLWLRQLQ ´E\SDVVµ RQO\
LI QHHGHG IRU VRIWHQHU UHSDLUV
FIG. 14FIG. 13 %<3$669$/9(6
3 - VALVE BYPASS
SINGLE BYPASS
KNOW ABOUT YOUR WATER SOFTENER

SECTION 4


3UREOHPV 4XHVWLRQV" &DOO    .HQPRUH :DWHU /LQH

A. DIMENSIONS / SPECIFICATIONS

Inches CM
ASalt Tank Height 40-1/4 102. 2
BResin Tank Diameter
(nominal) 820.3
CResin Tank Height
(nominal) 40 101.6
DInlet-Outlet Height 41-1/2 105. 4
EOverall Height 46 116.8
F1Length 19-1/2 49.5
F2Width 16-1/2 41.9
Distance between inlet-
outlet center lines 3-3/8 8. 6

ULTRASOFT 100 TIMERSRCODESR22

ULTRASOFT 150 TIMERSRCODESR24

1RWH 3OHDVH VHH WKH UDWLQJ GHFDO IRU RSHUDWLQJ FDSDFLW\ VDOW XVDJH DQG VHUYLFH IORZ UDWHSUHVVXUH ORVV
SHUIRUPDQFH VSHFLILFDW LRQV 3HUIRUPDQFH VSHFLILFDWLRQV DUH YDOLGDWHG E\ WKH :DWHU 4XDOLW\ $VVRFLDWLRQ
:4$ 7KH UDWLQJ GHFDO LV ORFDWHG RQ WKH ULP XQGHU WKH VDOW KROH FRYHU VHH SDJH $ LQVLGH IURQW FRYHU
WATER SUPPLY TO WATER SOFTENER UltraSoft100 UltraSoft 150
Minimumwater system flow (gpm) 3 3
Minimum-Max.water pressure (psi) 20 - 125 20 - 125
Minimum-Max.water temperature ( 40 -120 40 - 120
Maximum waterhardness (gpg) 95 95
Maximum ‘‘clearwater’’ iron (ppm) 45
SALT FOR WATER SOFTENER
Type of salt needed nugget or pellet
Alternatetype of salt pure, evaporated,compacted
water softenersalt
Salt storagecapacity (lbs) 200 200
S
E
C
T
I
O
N
4