CUSTOMER RESPONSIBILITIES
Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears, call
•CSA - Canadian Standards Association
•ANSI - American National Standards Institute
•NFPA - National Fire Protection Association
•ASME - American Society of Mechanical Engineers
•GAMA - Gas Appliance Manufacturers Association
•This
•Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the
•The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the current edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
•If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.
•Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1.
Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.
•For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from the California Office of the State Architect, 1102 Q Street, Suite 5100, Sacramento, CA 95811. Instructions can also be downloaded to your computer at WWW.dsa.dgs.ca.gov/Pubs.
•Complies with 10 ng/J SCAQMD rule #1121 and districts having equivalent NOx requirements.
PRODUCT SPECIFICATIONS
|
|
|
| RECOVERY | MINIMUM |
| DIMENSIONS IN |
| TANK |
| INPUT | RATE GALS. | VENT PIPE | DIAMETER | INCHES (mm) |
| CAPACITY IN | TYPE OF | RATE | PER HOUR @ | INCHES | INCHES | HEIGHT TO |
MODEL NUMBER | GALS (LTRS) | GAS | (Btu/hr) | 90°F RISE | (mm) | (mm) | JACKET TOP |
153.330660 | 40 (151) | NATURAL | 40,000 | 41.0 | 3 (76) OR 4 (102) | 20 (508) | 58 3/8 (1,483) |
|
|
|
|
|
|
|
|