accordance with applicable provisions of INSTALLATION OF OIL BURNING

IEQUIPMENT,or oil-fired boilersNFPAfor-31 connections- latest revision,to ventsandor applicablechimneys, provisionsvent installationsof local shallbuildingbe incodes.

CHIMNEY AND CHIMNEY CONNECTIONS

This is a very important part of your heating system. No boiler, however efficient its design, can perform satisfactorily if the chimney that serves it is inadequate. Check your chimney to make certain that it is the right size, properly constructed and in sound condition.

It is cheaper to rebuild a poor chimney than to pay excessive fuel bills. If yours is an old chimney, a new

steel liner or a new prefabricated chimney may be the best solution. The following chart shows

recommended minimum chimney sizes based on Table 3 and Figure 6 of the I=B=R Testing and Rating

Standard for Heating Boilers, Sixth Edition, June 1989.

RECOMMENDED MINIMUM CHIMNEY SIZES

FIRING RATE

CHIMNEY

NOMINAL

ROUND LINER -

 

SQUARE LINER -

CHIMNEY

INSIDE

 

INSIDE

 

 

 

 

 

(gph)

HEIGHT (ft)

AREA

DIAMETER

I

DIMENSIONS

1.31

-

1.80

15

8" x 8"

7"

I

6-3/4" x 6-3/4"

0.60

-

1.30

15

8" x 8"

6"

6-3/4" x 6-3/4"

1.81

-

2.00

20

8" x 8"

8"

 

6-3/4" x 6-3/4"

:or elevations above

2,000 feet above

sea level, add 3 feet to the chimney

heights. See Figure below.

For additional chimney design and sizing information, consult the ASHRAE 1996 HVAC Systems and

Applications Handbook, Chapter 30, Gas Vent and Fireplace Systems; or the National Standard for

Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances, ANSI/NFPA 211.

CHIMNEY CONNECTOR AND DRAFT REGULATOR

Venting

the

boiler

requires

 

a 6" diameter

 

chimney

connector

pipe

and

using

the

draft

regulator

packed

with

the boiler.

 

Properly

 

installed,

 

the

regulator

will

control

the draft

automatically.

 

It is

better

to install it

in a

horizontal

section

of

pipe,

but

it may

be

installed

 

in an

angled

or

vertical section

of

pipe.

Make

certain

that

the "top" of

the regulator

is

at

the

top

-

and that the short pipe

section

which

holds

the

vane is

horizontal.

Even

though

locating

the

draft

regulator

 

close

to

the chimney

reduces

noise,

install

 

the

draft

regulator

as

close

as

practicable

 

to the

boiler.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To install the chimney connector, start at the boiler with a vertical pipe and then elbow - then install the draft regulator making it horizontal. When the regulator is in place, start at the chimney and work back to the regulator. Join the two sections with a drawband. The horizontal pipe must slope up toward the chimney at least 1/4 inch per linear foot of venting. The chimney connector must not leak and must be firmly supported. Join each of the sections with at least two sheet-metal screws. Support every second section with a stovepipe wire.

Maintain a minimum vent pipe clearance of 18" from the surface of the vent to wood and other

combustible materials.

14

Page 16
Image 16
Kenmore 3E W.65, 4EW.90, 3EW.75, 5EW1.75, 5EW2.00, 5EWL.20 Chimney and Chimney Connections, Recommended Minimum Chimney Sizes

5EWL.20, 3E W.65, 4EW.90, 5EW2.00, 4EW1.50 specifications

The Kenmore lineup, featuring models 5EW1.75, 3EW.75, 4EW1.50, 5EW2.00, and 4EW.90, showcases a range of advanced technologies and features designed to enhance performance and efficiency in home appliances. These models highlight Kenmore’s commitment to innovation, aiming to meet the diverse needs of consumers for reliable and functional appliances.

The 5EW1.75 stands out with its efficient energy usage, designed for those who prioritize eco-friendliness without sacrificing performance. This model employs smart technology that optimizes energy consumption, making it not only cost-effective but also environmentally responsible. Additionally, it incorporates intuitive controls, allowing users to adjust settings easily and monitor energy levels in real-time.

Transitioning to the 3EW.75, this model focuses on durability and reliability. Constructed with high-quality materials, it promises a longer lifespan and reduced maintenance costs. The inclusion of quality components ensures consistent performance even under heavy use, appealing to families or individuals who value dependability.

The 4EW1.50, known for its versatility, features multiple settings suitable for various tasks. From quick washes to intense cycles, users can select the ideal program for their specific needs. This adaptability makes it a favorite among busy households. Coupled with a user-friendly interface, the 4EW1.50 encourages ease of use, which is a significant draw for consumers.

The 5EW2.00 takes efficiency to the next level, integrating cutting-edge washing technologies. With a focus on water conservation, this model uses advanced sensors to optimize water usage based on load size and fabric type. Additionally, its noise reduction capabilities ensure that operations remain quiet, a key factor for those in smaller living spaces.

Lastly, the 4EW.90 model blends style and function. With a sleek design, it enhances the aesthetic of any home while providing robust performance. It features modern connectivity options that allow for integration with smart home systems, bringing convenience to everyday tasks.

Together, these Kenmore models represent a balance of innovation, efficiency, and user-focused design. Whether addressing energy use, versatility, durability, or aesthetics, each model brings unique characteristics that cater to the evolving demands of consumers, solidifying Kenmore’s reputation as a leader in household appliance technology.