In case of difficulty

KAF-3010R/1010 (En)

What appears to be a malfunction may not always be serious. If your unit should not perform as expected, consult the table below

14 to see if the problem can be corrected before seeking help from your dealer or service representative.

Operation to reset

The microcomputer may fall into malfunction (impossibility to operate, erroneous display, etc.) when the power cord is unplugged while power is ON or due to an external factor. In this case, execute the following procedure to reset the microcomputer and return it to normal condition.

Set the POWER to OFF then, while holding down the SOURCE DIRECT key, set the POWER switch to ON.

Please note that resetting the microcomputer clears the contents stored in it and returns it to the condition when it left the factory.

Remote control unit (KAF-3010R only)

Symptom

Cause

Remedy

 

 

Remote control operation is not possible

Batteries are exhausted.

Replace with new batteries.

 

9

 

The remote control unit is too far away

Operate the remote control unit within the

 

from the main system, controlling angle is

controllable range.

 

9

 

too large, or there is an obstacle in be-

 

 

 

 

tween.

 

 

 

 

The audio cords and system control cords

Connect properly referring to “System

 

are not connected properly.

connection”.

45

 

The source component to be operated

Place the tape(s) or CD in the source com-

 

does not contain the tape(s) or CD.

ponent to be played.

 

 

 

The POWER switch is set to OFF.

Set the POWER switch to ON.

0

 

 

 

 

 

Amplifier

Symptom

Cause

Remedy

 

Sound is not output.

The speaker cords are disconnected.

Connect them properly referring to

“Sys-

 

The VOLUME CONTROL is set to the

tem connection”.

6

 

Adjust the volume to a proper level. 0

 

minimum position.

 

 

 

MUTING is ON.

Press the MUTING key to OFF.

!

 

(The MUTING indicator is blinking)

 

 

 

The SPEAKERS switches are set to OFF.

Set the SPEAKERS switch(es) to ON.

 

The system control cords are not fully con-

 

0

 

Check the system control connections.

 

nected.

45

 

 

 

The standby indicator blinks and sound

Speaker cords are short-circuited.

Turn the power off, eliminate the short-cir-

is not output. (KAF-3010R)

 

cuiting, then turn on the power again.

The MUTING indicator blinks and sound

 

 

 

is not output. (KAF-1010)

 

 

 

 

 

 

Sound is not output from one of the

The speaker cord is disconnected.

Connect it properly referring to “System

speakers.

The BALANCE control is set to an extreme

connection”.

6

 

Adjust the Left/Right balance.

!

 

position.

 

 

 

 

 

 

Speaker protection circuit

When this unit’s power is turned ON with the speaker cable short-circuited, the speaker protection functions.

If the standby indicator blinks (KAF-3010R) or the MUTING indicator blinks (KAF-1010) and no sound occurs, turn the power OFF, remove the short-circuit, then turn the power ON again.

Do not use contact cleaners because it could cause a malfunction. Be specially careful against contact cleaners containing oil, for

Note

they may deform the plastic components.