4
TK-860G/862G
REALIGNMENT

Clone Mode

Programming data can be transferred from one radio to
another by connecting them via their modular microphone
jacks. The operation is as follows (the transmit radio is the
master and the receive radio is the slave).
1. Turn the master TK-860G power ON with the [ ] key
held down. If the password is set to the TK-860G, the
TK-860G displays "CLN LOCK". If the password is not
set, the TK-860G displays "CLONE".
2. When "CLN LOCK" is displayed, only the [CH / ] key
and [SCN], and [0] to [9] keys can be accepted. When
you enter the correct password, and "CLONE" is dis-
played, the TK-860G can be used as the cloning master.
The following describes how to enter the password.
3. How to enter the password with the microphone keypad;
If you press a key while "CLN LOCK" is displayed, the
number that was pressed is displayed on the TK-860G.
Each press of the key shifts the display in order to the
left. When you enter the password and press the [SCN]
key, "CLONE" is displayed if the entered password is cor-
rect. If the password is incorrect, "CLN LOCK" is
redisplayed.
How to enter the password with the [CH / ] key;
If the [CH / ] key is pressed while "CLN LOCK" is dis-
played, numbers (0 to 9) are displayed flashing. When
you press the [SCN] key, the currectly selected number is
determined, and the display shifts to the left. If you press
the [SCN] key after entering the password in this proce-
dure, "CLONE" is displayed if the entered password is
correct. If the password is incorrect, "CLN LOCK" is
redisplayed.
4. Power on the slave TK-860G/862G.
5. Connect the cloning cable (No. E30-3382-05) to the
modular microphone jacks on the master and slave.
6. Press the [SCN] key on the master while the master dis-
plays "CLONE". The data of the master is sent to the
slave. While the slave is receiving the data, "–PC–" is dis-
played. When cloning of data is completed, the master
displays "END", and the slave automatically operates in
the User mode. The slave can then be operated by the
same program as the master.
7. The other slave can be continuously cloned. When the
[SCN] key on the master is pressed while the master dis-
plays "END", the master displays "CLONE". Carry out the
operation in step 4 to 6.

Note :

You can clone the programmed data between the trans-
ceiver frequency version must be same.
Cloning cable
(E30-3382-05)

Fig. 1

MBL
PSB
GND
PTT/TXD
ME
MIC
HOOK/RXD
CM
GND
REMOTE/TXD
PTT/RXD
8
1
1
8
Clone cable
E30-3411-05 (TK-860G → TK-360G/370G)