HOW TO USE

HOW TO USE

BE CAREFUL

Operate the heater in upright position only. Any other position could create hazardous situations!

ON/OFF Switches

POWER ECONOMIZER

For more economical use, the Min. or Med. power switches may be used individually, after unit has reached the operating temperature.

700500

WATTS WATTS

With pilot lights ON, the heater is ON!

1. LOCATION

Place the heater on the floor beneath the coldest window in the room or any desired location. Your heater will minimize the effect of cold drafts. The heater must not be located immediately below an outlet. Do not use this heater in rooms having a surface area less than 45 sq. ft (4 m2).

2. CONNECTION

The radiator must be connected to a properly polarized A/C 110/120 V household outlet in per- fect working conditions.

Keep loose clothing or bedding, furniture and flammable material away from the wall outlet where the heater plug is fitted in.

3. GROUND FAULT INTERRUPTION SAFETY DEVICE (GFI PLUG)

This device provides protection against electric shock due to ground fault currents by automatically shutting off the power. To test the operation of the GFI plug switch the

heater ON at either the 1 or 2 setting. Press the TEST button on the GFI plug device attached to the plug end of the power cord. The heater and fan should stop operating and the Power Light should turn off. Press the RESET button on the GFI plug device to resume normal operation of the heater. This device should not be used as on ON/OFF operation switch.

“CAUTION: ALTHOUGH THIS DEVICE IS PROVIDED WITH PROTECTION

WHICH REDUCES THE RISK OF ELECTRIC SHOCK, THIS PRODUCT SHOULD NEVER BE USED CARELESSLY NEAR WATER.”

INSTRUCTIONS FOR USE 4. USE OF THERMOSTAT

Turn thermostat clockwise to the maximum position. Switch on both switches. The lights on the swit- ches remain on independently from of the cycling of the thermostat. When the room reaches the desired temperature, turn the thermostat knob clockwise very slowly and carefully until you hear a “click”. This will automatically set your unit to cycle on and off at that desired heat setting. (For timer instructions, see point 5).

Note: It will normally require approx.15 minutes to reach operating temperature.