3.Diagnostics – Error Codes:
The B3000 contains
Below is a summary of all errors, their meanings and the menu messages.
ERROR CODES | MESSAGE DISPLAY | PROBABLE CAUSE |
01 | ERROR – TCO HIGH OPEN | MODULES: POWER, HWT |
CALL FOR SERVICE |
| |
|
| |
02 | ERROR – TCO LOW OPEN | MODULES: POWER, HWT |
| CALL FOR SERVICE |
|
|
| |
03 | ERROR – DESCALE NOW | DESCALE REQUIRED |
| CALL FOR SERVICE |
|
|
| |
04 | ERROR – CHECK WATER SUPPLY | MODULES: CWT, POWER |
| CALL FOR SERVICE |
|
|
| |
05 | ERROR – RUNAWAY FILL | MODULES: CWT, POWER |
CALL FOR SERVICE |
| |
|
| |
| ERROR – LOW TANK FROZEN | PREHEAT TANK COLD |
06 | CALL FOR SERVICE | MODULES: HWT |
|
| |
07 | ERROR – HIGH TANK FROZEN | BREW TANK COLD |
CALL FOR SERVICE | MODULES: HWT | |
|
| |
08 | ERROR – LOW TANK HI TEMP | MODULES: POWER, HWT |
CALL FOR SERVICE |
| |
|
| |
09 | ERROR – HIGH TANK HI TEMP | MODULES: POWER, HWT |
CALL FOR SERVICE |
| |
|
| |
10 | ERROR – COIN JAM | MODULES: COIN MECH |
CALL FOR SERVICE |
| |
|
|