4.Gently pull OUT and UP the valve assembly.

5.Reinstall the new valve.

NOTE: When reinstalling the new valve, you MUST make sure that the “O” ring on the bottom of the outlet tube is in place.

NOTE: The large Plastic Nut must be tight. Failure to do so will cause a leak when the hot water feature is selected.

6. Conduct a BIT test (see appendix VII on page 85) to insure the proper function of the brewer.

B3000 SERVICE MANUAL

 

60-200807-000, REV C

45