8. TROUBLE SHOOTING GUIDE
Problem | Possible cause | Solution | |
Not all of the | Devices may not all | Locate the | |
alarms/accessories | be on the same ID. | unit and ensure that all of the corresponding switches | |
produce an alarm |
| are set the same. If an ID needs to be changed: | |
signal when the Test |
| Remove power, change the ID and reapply power. | |
button is pushed on |
|
| |
a unit. | Devices may not have | Check to see if the Green LED is on continuously (this | |
| power. | tells you the alarm is receiving AC power) or that it | |
|
| blinks every ten seconds (this tells you that it is receiving | |
|
| only battery power). If not make sure the batteries are | |
|
| installed correctly and the AC outlet has power. If the | |
|
| alarm is not receiving AC power but is receiving battery | |
|
| (DC) power the green LED will flash every 10 seconds. | |
|
| Contact a qualified electrician to check power to the | |
|
| wires. | |
|
|
| |
| Button not pressed | Press and hold the button for a minimum of 5 seconds | |
| long enough. |
| |
|
|
| |
| There may be too | Move the other units to a new location and try again.. | |
| much interference | You should try to locate the Wireless units as closely to | |
| between units. | each other as possible. | |
|
|
| |
Units signal an | Unit is set to the | Change the ID of your units by following the instruc- | |
alarm when no fire | same ID as a system | tions in section 3. INSTALLATION INSTRUCTIONS, WIRE- | |
is present and none | nearby. | LESS INTERCONNECT SETUP. Make sure to power all the | |
of the test buttons |
| units off before changing the switch positions. | |
have been pushed. |
|
| |
Unit is located in area | Review section 2.LOCATIONS TO AVOID. Relocate the | ||
| |||
| prone to cause false | unit. | |
| alarms. |
| |
|
|
| |
| Wireless Interference. | Move the other units to a new location. | |
|
|
|