Bottom Mount Refrigerator
PRODUCT MODEL NUMBERS
KBLS19KT KBRS19KT
KBLS20ET KBRS20ET
KBLS22ET KBRS22ET
KBLS22KT KBRS22KT
Electrical: A 115 Volt, 60 Hz., AC only 15 or 20 amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your refrigerator be provided. Use an outlet that cannot be turned off by a switch. Do not use an extension cord.
Water: Connect the ice maker to a cold water line with water pressure between 35 and 100 psi
If a reverse osmosis water filtration system is connected to your cold water supply, the water pressure to the system needs to be a minimum of approximately 40 to 60 psi
IMPORTANT: The pressure of the water coming out of a reverse osmosis system going to the water inlet valve of the refrigerator needs to be between 35 and 100 psi
LOCATION REQUIREMENTS
¹⁄₂" (1.25 cm)
OVERALL DIMENSIONS
B
A
not incl. | 1 |
|
handle
D
overall
C
top of
cabinet
4
| Depth | Cab. Width | Cab. Height | Overall Height |
Model # | "A" | "B" | "C" | "D" |
KBLS19KT | 30 7/8" | 29 5/8" | 65 1/2" | 66 3/4" |
KBLS20ET | 26 7/8" | 35 5/8" | 68 1/2" | 69 3/4" |
KBLS22ET | 30 7/8" | 32 5/8" | 68 1/2" | 69 3/4" |
|
|
|
|
|
KBLS22KT | 30 7/8" | 32 5/8" | 68 1/2" | 69 3/4" |
KBRS19KT | 30 7/8" | 29 5/8" | 65 1/2" | 66 3/4" |
|
|
|
|
|
KBRS20ET | 26 7/8" | 35 5/8" | 68 1/2" | 69 3/4" |
|
|
|
|
|
KBRS22ET | 30 7/8" | 32 5/8" | 68 1/2" | 69 3/4" |
KBRS22KT | 30 7/8" | 32 5/8" | 68 1/2" | 69 3/4" |
To ensure proper ventilation for your refrigerator, allow for 1⁄2" (1.25 cm) space on each side, at the top and behind the refrigerator. When installing your refrigerator next to a fixed wall, leave 2 1/8" (5.4 cm) minimum on the hinge side to allow for the door to swing open. If your refrigerator has an ice maker, allow extra space at the back for the water line connections.
NOTE: Do not install the refrigerator near an oven, radiator, or other heat source, nor in a location where the temperature will fall below 55°F (13°C).
2¹⁄₈" (5.4 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. 12828153 |
Instructions packed with product. Specifications subject to change without notice. |