® 30" Freestanding and Slide-In Gas Range
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
KGRS807S KGSS907S
KGRS807X KGSS907X KGSK901S
Freestanding Range
GAS SUPPLY REQUIREMENTS
Use ³⁄₄" (1.9 cm) rigid pipe gas supply line to the range location. A smaller size pipe on long runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ¹⁄₂"
(1.3 cm) minimum. If local codes permit, it is recommended that new flexible metal tubing,
ELECTRICAL REQUIREMENTS
B
A
C
D*
E
F**
A. | " (14.6 cm) | E. Model/serial number plate | |
B. 30" (76.2 cm) | (located on the | ||
C. | 41 " (106 cm) overall height | side oven door trim) | |
F. 27 " (69.2 cm) max. from | |||
| with leveling legs screwed all | ||
| the way in. | handle to standoff at back | |
D. 36" (91.4 cm) cooktop trim | of range** | ||
|
height with leveling legs screwed all the way in*
A
F
E**
A. 30 " (77.6 cm)
B. 35" (90.5 cm) height to underside of cooktop edge with leveling legs screwed all the way in*
C. Model/serial number plate (located on the
B*
C
D
D30" (76.2 cm)
on models KGRS807XSP and KGSS907XSP) from handle to standoff at back of range**
F.23" (58.4 cm) countertop notch to rear of cooktop
is recommended. A time-delay fuse or circuit breaker is recommended.
*Range can be raised approximately 1" (2.5 cm) by adjusting | *Range can be raised approximately 1" (2.5 cm) by adjusting | ||
the leveling legs. | the leveling legs. | ||
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm) | ** |
|
|
|
| ||
countertop; front of oven door protrudes 1" (2.5 cm) beyond |
|
|
|
24" (61 cm) base cabinet. |
|
|
|
|
|
|
SLIDE-IN RANGE COUNTERTOP PREPARATION
The cooktop sides of the
If you have a square finish (flat) countertop and the opening width is 30" (76.2 cm), no countertop preparation is required.
Formed
CABINET OPENING DIMENSIONS
Tile countertops may need trim cut back ³⁄₈"
(1.0 cm) from each front corner and/or rounded edge flattened.
If countertop opening width is greater than 30" (76.2 cm), adjust the ³⁄₈" (1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to side; then front to back. If countertop is not level, range will not be level. Range must be level for satisfactory baking conditions.
30"
(76.2 cm) "
(1.0 cm)
30 "
(78.1 cm)
|
| 13" (33 cm) upper | For minimum | |||
|
| clearance to top | ||||
|
| cabinet depth | of the cooktop, | |||
|
| 30" (76.2 cm) min. | see NOTE. | |||
|
|
|
| |||
|
|
| opening width |
|
| |
18" (45.7 cm) |
|
| 30" (76.2 cm) |
|
| |
upper cabinet |
|
|
|
| ||
|
| min. opening |
|
| ||
to countertop |
|
|
|
| ||
|
| width |
|
| ||
|
|
|
|
| ||
|
|
| Grounded |
|
| |
|
|
| outlet |
|
| |
|
|
| This shaded area | Cabinet door | ||
|
|
| 6" |
| or hinge | |
5" (12.7 cm) min. |
|
| (15.2 cm) recommended for | |||
clearance from |
|
| installation of | should not | ||
6" |
| outlet or |
| extend into | ||
both sides of the |
|
| ||||
| junction box. | the cutout. | ||||
range to the side | (15.2 cm) | |||||
|
|
| ||||
wall or other |
| 7" (17.8 cm) |
|
| ||
combustible |
|
|
| |||
|
|
|
|
| ||
material. |
|
|
|
|
| |
Available area |
|
|
|
|
| |
for gas and electric |
|
|
|
|
| |
installation. |
|
| This shaded area |
|
| |
|
|
| recommended for |
|
| |
|
|
| installation of |
|
| |
|
|
| rigid gas pipe. |
|
|
|
| 13" (33 cm) max. |
| For minimum | ||
|
|
| clearance to top | |||
| upper cabinet depth | of the cooktop, | ||||
|
| 30" (76.2 cm) min. | see NOTE. | |||
|
|
|
| |||
|
|
| opening width |
|
| |
18" (45.7 cm) |
|
|
| 22 | " (58.3 cm) | |
|
|
| opening depth | |||
upper cabinet |
|
|
| |||
|
|
|
|
|
| |
to countertop |
|
|
|
|
|
|
|
|
| 30" (76.2 cm) |
|
| |
|
|
| min. opening |
|
| |
|
|
|
| width |
|
|
|
|
|
| Grounded |
|
|
5" (12.7 cm) min. |
|
| 6" | outlet |
| Cabinet door |
|
|
|
| or hinge | ||
|
| (15.2 cm) This shaded area | ||||
clearance from |
|
| ||||
|
|
| recommended for | should not | ||
both sides of the |
|
|
| |||
6" |
|
| installation of | extend into | ||
range to the side |
|
| ||||
|
| outlet or |
| the cutout. | ||
wall or other | (15.2 cm) |
|
| |||
| junction box. |
|
| |||
combustible |
| 7" (17.8 cm) |
|
| ||
|
|
|
| |||
material. |
|
|
|
|
|
|
This shaded area |
|
|
|
|
|
|
recommended for |
|
|
| Available area |
|
|
installation of |
|
|
| for gas and |
|
|
rigid gas pipe. |
|
|
| electric |
|
|
|
|
|
| installation. |
|
|
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024"
(0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10246118C |
Instructions packed with product. Specifications subject to change without notice. | 1/28/11 |