KitchenAid KHMS2050S dimensions Microwave Hood Combination, Product Model Numbers

Models: KHMS2050S

1 1
Download 1 pages 57.98 Kb
Page 1
Image 1
Microwave Hood Combination

®

Microwave Hood Combination

PRODUCT MODEL NUMBERS

KHMS2050S

CABINET OPENING DIMENSIONS

AB

Electrical: A 120-volt, 60-Hz, AC-only, 15- or 20-amp electrical supply located in the upper cabinet as close as possible to the microwave oven hood. A time-delay fuse or circuit breaker and separate circuit is recommended.

OVERALL DIMENSIONS

18¹⁄₄"

(46.4 cm)

29

⁷⁄₈" (75.9 cm)

 

30"

 

(76.2 cm)

33"

min.

 

(83.2 cm)

 

typical*

12" (30.5 cm) min.

 

 

13" (33.0 cm) max.

69" (175.3 cm) min.

 

NOTE: The grounded 3 prong outlet must be inside the upper cabinet.

*33" (83.2 cm) is typical for 69" (175.3 cm) installation height. Exact dimension may vary depending on type of range/cooktop.

15¹⁄₂"

(39.4 cm)

18¹⁄₈"

(46.0 cm)

A. 2" x 4" wall stud

B. Grounded 3 prong outlet

VENTING REQUIREMENTS

Roof venting

roof cap

Wall venting

Recommended vent length

 

 

 

 

 

 

wall cap

Use 3-1/4" x 10" or 6" vent. The total length of the vent system

 

 

including straight vent, elbow, transitions, wall or roof caps

 

 

 

 

 

 

must not exceed the equivalent of 140 feet of

 

 

 

3-1/4" x 10" rectangular or 6" diameter round vent. For best

 

 

 

performance, use no more than three 90° elbows. To calculate

 

 

3-1/4" x 10"

the length of system you need, add the equivalent feet for

 

 

through-the-wall

each vent piece used in the system. See examples below.

 

3-1/4" x 10"

 

 

 

 

 

through-the-roof

 

3-1/4" x 10" vent system

Recommended standard fittings

For wall or roof venting methods:

 

 

 

 

 

If the wall exhaust method is chosen, be sure that

3-1/4" x 10"

 

 

 

 

 

 

 

90° elbow

6 ft.

wall cap

 

 

 

 

there is proper clearance within the wall so the vent

 

 

 

 

 

 

 

 

 

 

 

 

fits properly and the damper blade opens fully.

 

 

 

 

 

 

 

 

Wall and roof caps must have back-draft damper.

 

 

 

 

 

 

 

 

We recommend:

2 ft.

1 - 3-1/4" x 10"

 

 

 

 

 

 

using rigid metal vent.

 

 

3-1/4" x 10"

3-1/4" x 10"

3-1/4" x 10"

 

90° elbow

= 25 ft.

that length of vent and number of elbows should

 

 

 

 

to 6" = 5 ft.

roof cap = 24 ft.

90° elbow = 25 ft.

 

1 - wall cap

= 40 ft.

 

 

 

 

be kept to a minimum to provide efficient

 

8 feet straight

=

8 ft.

 

 

 

 

performance.

 

Length of

 

 

 

 

 

 

that size of vent should be uniform.

 

3-1/4" x 10" system

= 73 ft.

 

 

 

 

using duct tape to seal all joints in the vent

 

 

 

 

 

6" vent system

 

 

 

 

 

 

 

system.

 

 

 

 

 

 

 

 

 

 

 

90° elbow

3-1/4" x 10"

45° elbow

3-1/4" x 10"

using caulking compound to seal exterior wall or

90° elbows

6 ft.

 

wall cap

6" = 10 ft.

wall cap =

6" = 5 ft.

90° flat

roof opening around cap.

 

 

 

 

 

40 ft.

 

elbow= 10 ft.

two elbows should not be installed together.

 

 

 

 

 

 

 

 

 

 

 

 

If the existing vent is round, a rectangular- to-round adapter must be used and a rectangular 3" extension vent between the damper assembly and the adapter must be installed to prevent sticking of the exhaust damper.

We do NOT recommend:

 

 

 

 

 

 

1

- transition

=

5 ft.

 

 

 

 

 

 

 

 

 

2 ft.

flexible metal vent.

 

 

 

2

- 90° elbows

= 20 ft.

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: If flexible metal vent must be used, calculate

 

 

 

 

 

 

1

- wall cap

= 40 ft.

 

 

 

 

 

 

 

 

 

 

 

 

8 feet straight

=

8 ft.

each foot of flexible metal vent as two feet of rigid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Length of 6" system

= 73 ft.

metal vent. Flexible metal elbows count twice as

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

much as standard elbows.

 

 

 

 

 

 

 

 

 

 

transition

 

 

 

 

 

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. 8206329

Instructions packed with product. Specifications subject to change without notice.