5
Cutout Dimensions
Clearance Dimensions

Electrical Requirements

Recommended Grounding Method
This compactor is for use on a single phase, 115-volt, 60 Hz, AC
only 15- or 20-amp fused and properly grounded circuit and is
equipped with a grounding plug as shown below. It is
recommended that a separate circuit serving only this appliance
be provided.
This compactor must be grounded while in use to reduce the risk
of electric shock. The compactor is equipped with a three-
conductor cord and 3 prong grounding-type plug to fit the proper
grounding-type receptacle. The green (or green and yellow)
conductor in the cord is the grounding wire. Do not connect the
green (or green and yellow) wire to a live terminal.
A.Grounded eletrical outlet must be a minimum
of 3" (7.6 cm) away from surrounding cabinets
or nearby walls as shown. It can be placed
either to the left or the right side of the
compactor.
A.Leave 6" (15.2 cm) of clearance space to the right side of
the compactor in order to remove the compactor bags.
B.Leave 23" (58.4 cm) of clearance in front of the compactor
in order to fully open or remove the compactor drawer.
A
24" min.
(61 cm)
34¹⁄₄" min.
(87 cm)
18" min.
(45.7 cm)
3" min.
(7.6 cm)
15¹⁄₄" min.
(38.7 cm)
BA
WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Failure to follow these instructions can result in

death, fire, or electrical shock.

Do not use an extension cord.

Do not use an adapter.

Do not remove ground prong.