RCA 2600 Series Installation/Operation Guide | KMC | |
KELLY MANUFACTURING COMPANY |
|
SECTION 4, GENERAL INFORMATION
4.1Instrument Care
The most easily damaged part of your instrument is the screen. Special care should be taken when cleaning the screen to prevent scratches and other damage. Avoid touching the screen at all times.
To clean light spots and dust, use a soft, lint free cotton cloth slightly moistened with distilled water.
For harder to clean spots, use a 50/50 solution of isopropyl alcohol and distilled water. Vinegar may also be used in a 50% solution with water. You may also use cleaners approved for LCD TV’s and laptop computer screens.
Always apply the cleaner to the cloth and not the screen.
●● Do Not use paper towels, facial tissue or napkins. These products are made from recycled paper and may contain metals and wood chips that will scratch the screen.
●● Do Not use acetone or cleaners containing ammonia.
By avoiding all screen contact and by using proper cleaning methods, the user will be rewarded with many years of service.
4.2OPTIONAL SLIP INDICATOR
An optional Slip/Skid Indicator (inclinometer)is available for the
INSTALLATION
1.Apply power to the instrument to assure that it reads level in pitch and roll.
2.Remove two screws on the face of the instrument.
3.Align Inclinometer with holes and replace screws. Do not tighten.
4.Adjust the Inclinometer until the bubble is centered and tighten screws just enough to secure Inclinometer. Do not over tighten.
SLIP INDICATOR
SCREWS
Figure 4.1, Inclinometer Installation
Page 8 of 10 | KMC Publication | Rev C |