Knoll Systems MA1250 specifications Link out position, cascades channel, to chanels, 120 VAC, Amps

Models: MA1250

1 4
Download 4 pages 50.12 Kb
Page 4
Image 4
MA1250

10.Connect the AC power into an outlet that supplies at least six amps (750 watts) dedicated to each MA1250.

Caution: Never listen to sound that is distorted. If distorted sound is heard, turn the volume down immediately or speaker and/or amplifier damage could occur that is not covered by the warranty. If this problem persists, contact your dealer.

User adjustments and service: There are no user adjustments on the MA1250. Your installer may make certain gain level adjustments on the rear panel.

Caution: The MA1250 contains no user serviceable parts, so do not attempt to open or repair the MA1250. Refer servicing to a qualified technician only or contact the factory for information.

The trigger is 12 VDC (35mA per MA1250) via 3.5mm mono jack. 5 VDC trigger outputs will not work. To connect the trigger to a receiver use a 12 VDC power supply (we suggest Knoll PS1202 power supply with an adaptor). Plug the power supply into the switched outlet on the rear of the receiver. Connect the 12 volt wire to a 3.5mm mono jack. Plug the jack into the rear of the MA1250. 12 VDC polarity is not important. Make sure the amplifier power switch is off (out). When the receiver is switched on, the MR1250 amplifier is switched on.

 

 

Input

 

 

Input

 

 

Input

12 VDC

 

 

 

 

 

 

Trigger

 

 

1

2

 

 

3

4

 

 

5

6

Output

L

Output Output

 

Output Output

L

Output

 

Gain

 

 

Gain

Gain

L

Gain

Gain

 

 

Gain

 

R

 

 

 

 

 

 

 

R

 

 

 

 

1L 1R

 

 

2L 2R

3L 3R

R

4L 4R

5L 5R

 

 

6L 6R

 

 

 

 

 

 

 

 

MA1250

 

Link (out position)

 

120 VAC

cascades channel 1

 

 

8 Amps

to chanels 2-6

 

 

 

Caution: NEVER connect the MA1250 to impedances less than 4 ohms or amplifier damage not covered

by the warranty may occur.

The Link button is normally set to the in Link (out position) position to give all six stereo inputs individual 120 VAC sources. When the Link button is set to the

out position, that input Left/Right is linked or

cascaded to input #1 (without the use of Y cords). Any or all combination of linked inputs 2 to inputs 6 are possible. When all inputs are linked to input 1 the input impedance is about 4000 ohms.