Characteristic Curve | Spectral Sensitivity Curve |
Kodak COM DR Microfilm 2467/Estar Base
Kodak COM Professional Developer and Replenisher DRC
95°F (35°C), 3.6 fpm;
Diffuse visual
3
2
Density
1
0 |
|
|
|
|
|
|
0.00 | 1.00 | 2.00 | 3.00 |
Log Exposure (lux seconds)
Kodak COM DR Microfilm 2467/Estar Base
Kodak COM Professional Developer and Replenisher DRC
|
|
|
|
| 36 sec., 95°F (35°C); |
|
|
|
| |||
|
|
|
|
| 1.4 sec. exposure |
|
|
|
| |||
|
| 2 |
|
|
|
|
|
|
|
|
|
|
| require | 1 |
|
|
|
|
|
|
|
|
|
|
| cm) |
|
|
|
|
|
|
|
|
|
|
|
Log Sensitivity | reciprocal of exposure (ergs/sq | 0 |
|
|
|
|
|
|
|
|
|
|
to produce specifieddensity) |
|
|
|
|
|
|
|
|
|
| ||
| = |
|
|
|
|
|
|
|
|
|
|
|
| (Sensitivity |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| D=1.0 fixed |
|
|
|
|
|
|
|
|
|
|
|
| D=.15 fixed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 250 | 300 | 350 | 400 | 450 | 500 | 550 | 600 | 650 | 700 | 750 |
Wavelength (nm)
Modulation Transfer Function Curve
Kodak COM DR Microfilm 2467/Estar Base
35% Modulation
1000
100
RESPONSE (%)
10
1
1 | 10 | 100 | 1000 |
SPATIAL FREQUENCY (cycles/mm)
The MTF curve was determined using a method similar to that described in ANSI
Process Cycle Adjustment Guide
Equivalent Time/Temperature Conditions
(°F) | 101 |
|
|
|
100 |
|
|
| |
99 |
|
|
| |
TEMPERATURE |
|
|
| |
98 |
|
|
| |
97 |
|
|
| |
96 |
|
|
| |
95 |
|
|
| |
94 |
|
|
| |
93 |
|
|
| |
92 |
|
|
| |
DEVELOPMENT | 91 |
|
|
|
90 |
|
|
| |
89 |
|
|
| |
88 |
|
|
| |
87 |
|
|
| |
86 |
|
|
| |
85 |
|
|
| |
84 |
|
|
| |
| 35 | 40 | 60 | |
| 23 |
DEVELOPMENT TIME (seconds)
The above chart can be used to determine other development time/temperature combinations that provide equivalent photographic quality. Temperatures between 90 and 100°F (32 and 37.8°C) are optimum for total system performance.
Notice: While the data presented are typical of production coatings, they do not represent standards which must be met by Eastman Kodak Company. Varying storage, exposure, and processing conditions will affect results. The company reserves the right to change and improve the product characteristics at any time.
After-Process Information
Keeping
This film is suitable for archival keeping when processed as recommended. However, due to possible variations in conditions, it is recommended that users establish their own compliance with existing
4 |