GE680 User Manual

70-0026A-A

Item 1: GIGABIT ETHERNET PORT

This port conforms to the IEEE 802.3 1000BASE-T standard for Gigabit Ethernet over copper. It is recommended that CAT5E or CAT6 compatible cabling and connectors be used for best performance. Cable lengths up to 100m are supported.

Item 2: General Purpose I/O PORT

 

 

9

1

 

8

 

 

10

 

 

 

 

 

12

11

2

7

 

 

 

 

3

6

 

5

4

 

PIN FUNCTION

1Trigger Input

2Sync Out 2

3Sync Out 3

4RS-232 RXD

5RS-232 TXD

6DNC

7DNC

 

8

DNC

 

9

DNC

 

10

Isolated Ground

 

11

Isolated Ground

Figure 3. General Purpose I/O Pin out. Camera

12

Isolated Ground

rear view.

 

 

The General Purpose I/O port uses a Hirose HR10A-10R-12SB connector on the camera side. The mating cable connector is Hirose HR10A-10P-12P. This connector can be purchased from Prosilica or from http://www.digikey.com.

All inputs and outputs are 5V (TTL) levels.

DO NOT EXCEED 5.5V ON SIGNAL INPUTS.

All inputs and outputs are galvanically isolated from the internal camera circuitry.

TRIGGER INPUT

This input signal allows the camera to be synchronized to some external event. The camera can be programmed to trigger on the rising or falling edge of this signal. The camera can also be programmed to capture an image at some programmable delay time after the trigger event.

Prosilica Inc.

6

Page 8
Image 8
Kodak GE680C user manual Item 1 Gigabit Ethernet Port, Item 2 General Purpose I/O Port