SETTING THE MIDI CHANNEL (GLOBAL “MIDI CH”)
In order to exchange data with an external MIDI device, your AX3000B’s MIDI
channel must match the MIDI channel of your external MIDI device. Here’s how to
set the MIDI channel.
1. Press the GLOBAL button.
2. The name display will show “MIDI CH.” If a different parameter is selected,
press the √√
√√/®®
®® buttons to change the display.
3. Use the value knob 1 or the ▲/▼ buttons to set your AX3000B’s MIDI channel.
4. Set the MIDI channel of your connected external MIDI device.
HINT: For details on how to set the MIDI channel of your external MIDI device, refer
to its owner’s manual.
PROGRAM CHANGE (GLOBAL “PCHG OUT”)
When you switch programs on the AX3000B, a program change message is trans-
mitted from the MIDI OUT jack, causing an external MIDI device to switch pro-
grams. Similarly, when the AX3000B receives a program change message, its
program will switch automatically.
Here’s how you can specify whether a program change message will be transmit-
ted from the MIDI OUT jack when you switch programs on your AX3000B.
NOTE: Program change numbers not used by the AX3000B will be ignored. For
details on the range of program change numbers used by the AX3000B, refer to
End of this manual.
1. Press the GLOBAL button.
2. Press the √√
√√/®®
®® buttons to make the name display show “PCHG OUT.”
3. Specify whether program change messages will be transmitted. Use value
knob 1 or the ▲/▼ buttons to make the desired setting.
“OFF”: Program change messages will not be transmitted.
“On”: Program change messages will be transmitted.
CONTROL CHANGE (GLOBAL “CCHG I/O”)
When you operate the EXPRESSION pedal, Control switch or program switches of
the AX3000B, control change messages will be transmitted. This means that func-
tions for the corresponding control change numbers on an external MIDI device can
be controlled in realtime.
Similarly, when the AX3000B receives control change messages from an external
MIDI device, it will be controlled in the same way as if its own foot controller were
operated.
For a list of the functions that can be controlled from an external MIDI device, refer to
step 4.
Here you can specify whether the AX3000B will transmit and receive control change
messages.