Acquiring the EDID
Table 5: TP Connector Pinout
EIA /TIA 568A
PIN | Wire Color |
1Green/White
2Green
3Orange/White
4Blue
5Blue/White
6Orange
7Brown/White
8Brown
|
|
Pair 1 | 4 and 5 |
Pair 2 | 3 and 6 |
Pair 3 | 1 and 2 |
Pair 4 | 7 and 8 |
EIA /TIA 568B
PIN | Wire Color |
1Orange/White
2Orange
3Green/White
4Blue
5Blue/White
6Green
7Brown/White
8Brown
|
|
Pair 1 | 4 and 5 |
Pair 2 | 1 and 2 |
Pair 3 | 3 and 6 |
Pair 4 | 7 and 8 |
1234 5678
12 | 4 5 | 78 | 36 |
Figure 6: TP Connector
6Acquiring the EDID
The
To load the default EDID:
1.Plug the 12V DC power adapter into the power socket on the
2.With no display device connected to the
3.The EDID STATUS LED flashes rapidly several times and the new EDID is copied.
To capture the EDID information from a display device:
1.Using a short cable1, connect the XGA INPUT
2.Connect power to the display and switch it on.
3.Plug the 12V DC power adapter into the power socket on the
4.Press the EDID CAPTURE button.
5.The EDID STATUS LED flashes slowly several times and the EDID is captured.
6.Disconnect the display.
1 For example, Kramer model number