TROUBLESH OOTING

Carafe or Mug not detected (flashing brew light)

IRD cannot detect flat black or clear glass mug (change mug color)

IRD window is dirty (wipe with moist towel and dry)

Mug not close enough to IRD (move farther into brewer)

IRD is not set properly, call for technical service.

Water dripping from spray head

Spray head plugged (replace or clean spray head)

Normally, some water will drip from the spray head shortly after brewing

Slight valve leak (debris inside valve, disconnect water and reconnect, run 1-2 full cycles of water in carafe to dislodge debris and check)

Valve leak permanent, call for technical service.

Water dripping down walls of carafe area

Spray head plugged (replace or clean spray head)

Spray head leak around threads, (remove spray head, clean and re-install for tight fit)

Coffee not staying warm

Possible carafe vacuum failure (if carafe is warm to touch, replace carafe)

Preheat carafe before brewing coffee especially if used for half pot. (run brew cycle without filter or coffee)

Check volume of water by running a full cycle of water without coffee. If carafe overfills call for technical service.

Water leak from back of brewer

Check quick connect (push connectors together firmly and slightly twist)

Poly line leak at brewer, call installer to repair.

Valve connection leak, call for technical service.

PARTS & SERVI CE

Spare parts are available from Lance Larkin™ (866) 268-5953 or email info@lancelarkin.com. Contact Lance Larkin™ for all service and warranty issues.

Spray head

Brew Basket(s)

Carafe and lid

Mounting screws

Auxiliary water pump and (5) gallon jug.

For installation in areas without water supply.

11

12

Page 8
Image 8
Lance-Larkin BE-112 manual Parts & Servi CE