Lanier FX-061 manual Material Safety Data Sheet

Models: FX-061

1 2
Download 2 pages 22.09 Kb
Page 1
Image 1
MATERIAL SAFETY DATA SHEET

Lanier Worldwide, Inc.

2300 Parklake Dr., N. E.

Atlanta, GA 30345-2979

Emergency Telephone: (800) 526-4371

MATERIAL SAFETY DATA SHEET

Section 1: Chemical Product and Company Information

Identity:

Black Print Cartridge for M3110 / 3120

MSDS No.

FX-061

Product ID:

491-0273

Issued:

07/13/00

 

 

Supersedes:

12/01/98

Synonyms

 

Date:

07/13/00

& Common

Ink, Ink Cartridge, Print Cartridge

Prepared by:

EH&S Department 770-493-9500

Names:

 

Approved by:

Larry Choskey, EHS Manager

 

Lanier 3110, 3120, 3750 Fax

European Contact:

Lanier Worldwide , WSM Europe,

Uses:

 

Walter Fricke,

 

 

 

 

 

Im Taubental D-41468 Neuss, Germany

Chemical

Liquid

 

+49-2131-387-177

Formula:

 

 

 

 

 

Section 2: Composition / Information on Ingredients

 

PERCENT

CAS No.

EXPOSURE LIMITS

SOURCE

Water

85

- 95

7732-18-5

Not listed

n/a

Tetraethylene Glycol

1

- 2

112-60-7

Not listed

n/a

Glycerol

3

- 7

56-81-5

15mg/ m3 (1)

OSHA PEL ACGIH TWA

 

 

 

 

10mg/ m3 (1)

 

Black dye

1

- 3

Trade secret (2)

Not listed

N/a

Triethanolamine

.5 - 2

102-71-6

5mg/ m3

n/a

(1) Mist only (2) New Jersey Trade Secret Registration no.:

80100451-5008p

 

 

Section 3: Hazards Identification

HMIS Rating:

 

FLAMMA BILITY = 1

HEALTH = 1

REACTIVITY = 0

SPECIAL = none

Health Hazards

 

 

Short Term Exposure

 

Long Term Exposure

Inhalation

 

Information on ink constituents indicates short-term

 

No adverse chronic effects known from

 

 

harmful health effects are not expected from vapor

 

vapor generated during intended use at

 

 

generated during intended use at ambient conditions.

 

ambient conditions.

Skin Contact

 

Tests on inks indicate low acute dermal toxicity. Tests

 

No adverse chronic effects known.

 

 

indicate inks are not dermal sensitizers. Inks may be

 

 

 

 

slightly irritating to skin.

 

 

Eye Contact

 

Tests on inks indicate slight conjuctival irritation.

 

No adverse chronic effects known.

Ingestion

 

Tests on inks indicate low acute oral toxicity. May cause

 

No adverse chronic effects known.

 

 

GI discomfort.

 

 

Section 4: First Aid Measures

 

Remove to fresh air if effects occur. Get medical

 

In case of contact, immediately flush eyes with

Inhalation:

attention if needed.

Eye Contact:

water for 5 minutes. Get medical attention if

 

 

 

needed.

Skin Contact:

Wash with soap and water.

Ingestion:

Dilute stomach contents with several glasses

 

 

 

of water. Get medical attention.

Section 5: Fire Fighting Measures

Suitable extinguishing media: CO2, dry chemical, foam or water.

Extinguishing media which may not be used for safety reasons: none

Page 1
Image 1
Lanier FX-061 manual Material Safety Data Sheet