MATERIAL SAFETY DATA SHEET
Page 2 of 3 |
Section 6: Accidental Release Measures
Spill / leak Procedures: If spilled, sweep up using an approved toner vacuum with a 0.5 micron filter or smaller, such as the Atrix
AAAToner Vacuum or 3M Toner Vacuum. Use of a vacuum cleaner not rated for toner particles, could result in a fire or personal injury. Remove residue with soap and cold water.
Miscellaneous: Keep product out of sewers and watercourses.
Personal protection: Avoid inhalation of dust.
Section 7: Handling and Storage
Special Handling: Cleanse skin after contact before breaks or meals, and end of workday. Do not handle in areas where the wind blows.
Minimize the breathing of dust.
Special Storage: Avoid direct sunlight. Keep out of reach of children. Store in a cool, dry place. Below 35C (95F)
Section 8: Exposure Control and Personal Protection Information:
Respiratory Protection: none required under normal use.
Eye Protection: none required under normal use.
Hand Protection: none required under normal use.
Skin Protection: none required under normal use.
Section 9: Physical and Chemical Properties
CHARACTERISTICS: | Cyan | Melting point: | N/a |
Appearance: | |||
Form: | Powder | Vapor pressure: | N/a |
Odor: | Slight plastic odor | Vapor density: | N/a |
Solubility in Water: | Insoluble | Evaporation rate: | N/a |
Specific gravity: | ~ 5 g/cm3 | Boiling point: | N/a |
| Section 10: Stability and Reactivity |
Conditions to avoid: none | Hazardous decomposition products: will not occur |
Polymerization: none |
|
|
|
| Section 11: Toxicological Information: |
Ames test: negative
Acute oral toxicity: > 5000mg/kg
Carcinogenicity: no data is available on this product.
Teratogenicity: not available
Section 12: Environmental / Ecological Information
Bioaccumulation: Not known in bioaccumulation
Environmental degradation: not known
Section 13: Disposal Consideration
Used developer should be disposed of under conditions that meet all federal, state and local environmental regulations. Disposal regulations vary from locality to locality; therefore consult your local Lanier office or the EPA to determine the proper method for disposal. Do not incinerate loose or spilled developer.