OPERATION

MODEL 5586

MODELO 5586

OPERATION

1.Place the Heater on a firm, level surface, after assembling per this manual.

WARNING: Plastic or rubber tabs, like the feet on this unit, may stick to furniture surfaces and/or hardwood floors. The unit may leave a residue that could darken, stain or leave permanent blem- ishes on the finish of certain furniture surfaces, including wood surfaces, and/or hardwood floors.

2. Plug the cord set into a 120 volt outlet.

Be sure that the plug fits tightly into outlet.

When plugs fit loosely into receptacles, they may slip partially or completely out of the receptacle with only the slight movement of the attached cord. Receptacles in this condition may overheat and pose a serious fire hazard; if covered by a curtain or drape, the fire hazard is even greater.

3.When the Heater is initially plugged in, there will be a “beep” and the Power Light will come on indicating that there is power to the unit. The Power Light will remain lit until the Heater is unplugged from the electrical outlet. (Figure 1)

4.Turn the Heater ON by pressing the Power Button (Be sure that the plug fits tightly into outlet.).

5.When initially turned on, the Heater will display the current room temperature in ° Fahrenheit. Press the (OSCILLATION:) and ( ) buttons at the same time to change the display to ° Celsius. Press the same two buttons together again to change the display back to ° Fahrenheit.

6.Upon turning the Heater on, the unit will be in HIGH heat (TIMER FUNCTION (Figure 2)AUTOMATIC TEMPERATURE CONTROL Figure 3Display reflects High Heat and ) (1500 Watts) and will display the current room temperature. (Figure 1)

Display when initially turned on

Top view of controls

Figure 1

7.Press the (ARMADO (Figuras 1 a 5)Manual background) button for LOW heat (Manual backgroundManual background).

8.To turn the Heater OFF, press the Power Button (Manual background) and unplug the Heater from the electrical outlet.

OSCILLATION:

Pressing the Oscillation Button (Manual background) will allow the Heater to oscil- late back and forth. To stop the oscillation, press the Oscillation Button (Manual background) again. When the Heater is in Automatic Temperature Control, the oscillation function will stop when the set temperature is reached and resume when the Heater turns back on.

TIMER FUNCTION (Figure 2)

The timer function may be activated when the Heater display is in any function or speed. This function allows you to set the length of time the Heater will run before turning itself off, from 1 hour to 8 hours. Pressing the Timer Button (Manual background) will increase the length of time by 1 hour each time this button is pressed. After the display reflects 8 hours, pressing the Timer Button (Manual background) once more will reset the Heater to run continuously. The Heater will turn off when the set time has elapsed. The unit can be turned back on by pressing the Power Button (Manual background).

Timer Function in

Timer Function in

High Heat and Automatic

Low Heat

Temperature Control

Figure 2

AUTOMATIC TEMPERATURE CONTROL Figure 3

The automatic temperature function will only operate on "High" heat ( Manual backgroundManual backgroundManual background ). You cannot set the temperature automatically when the unit is in the low heat mode.

1.To set the room at a specific temperature press the (Manual background) or ( ) buttons to the desired temperature. The display will now reflect the (Manual background) and the temperature will be flashing. The Heater is now in Auto Temperature Mode.

2.When you reach the temperature at which you want to set the unit, the set temperature will flash several times and then the display will return to indicate the current room temperature and will gradually change as the room temperature changes. NOTE: the temperature display does not indicate the temperature of the heated air being emitted by the heater.

3.Once the room temperature reaches 2 degrees above the set temperature, the Heater will shut off. Once the room tempera- ture reaches 1 degree below the set temperature, the Heater will turn back on and continue to cycle off and on to maintain the set temperature.

4.This function will cancel if the (Manual backgroundManual background) button is pressed. The Heater will now be in High heat ( Manual backgroundManual backgroundManual background ) and run continuously.

NOTE: It is normal for the Heater “fan” to run for approximately 15 seconds when the Heater shuts off after reaching the set temperature.

Display reflects High Heat and

Automatic Temperature Control Function

ARMADO (Figuras 1 a 5)

Herramientas Necesarias: Destornillador de Cabeza #2 Phillips (no incluido)Retire cuidadosamente el Calentador de su bolsa y caja. Para facilitar el armado, coloque el Calentador de manera que la parrilla frontal y el panel de control den hacia arriba.

(4) - M5 X 13mm (2) - M4 X 13mm

Tamaño Real De Tornillos

Figura 1

1.Arme la base enclavando las Protuberancias en los Orificios para Protuberancias. (Figura 2)

Protuberancias Manual backgroundManual background

Orificios

para

Protuberancias

Llave

Figura 2

2.Fije las mitades de la base con (2) tornillos M4 X 13 mm. Pase el Cable Eléctrico por el gran orificio que se encuentra del Conjunto de la Base. NOTA: El Canal Para Cable en la parte inferior de la base debe estar hacia la parte posterior del Calentador.

(Figura 3)

Canal Para

Cable

Cable

Eléctrico

 

Conjunto de

la Base

3.Alinee el Conjunto de la Base con el Conjunto de Soporte de Columna. Cerciórese de que la Muesca de Ubicación en el Conjunto de Soporte de Columna quede alineada con la Llave en el Conjunto de la Base (Figura 4). Una el Conjunto de la Base al Conjunto de Soporte de Columna con (4) tornillos M5 X 13 mm. Jale suavemente el Cable Eléctrico para que no quede holgado, y colóquelo en el Canal Para Cable del Conjunto de la Base. (Figura 5)

Muesca de

Ubicación

Llave Manual backgroundManual backgroundManual background

Figura 4

Conjunto de

la Base

Conjunto de

Soporte de

Columna

Cable Eléctrico

Manual backgroundCanal Para

Cable

 

 

Figure 3

New 5/10

4

5586ES

Figura 3

 

Figura 5

 

 

New 5/10

9

5586ES

Page 4
Image 4
Lasko 5586, 5566 manual Modelo, Operation, Oscillation, TIMER FUNCTION Figure, AUTOMATIC TEMPERATURE CONTROL Figure