Storage of constants / historical storage

Storage of a constant

You can store and recall a frequently used value e.g. height of a room.

Measure the desired distance, press and hold the button until the device beeps to confirm storage.

Recalling the constant

Press this button once to recall the constant and then press the button to enter it into your calculation.

Historical storage

Press this button twice and the previous 20 results (measurements or calculated results) are shown in reverse order.

The and buttons can be used for navigation.

Press this button to use a result from the summary line for further calculations.

Pressing the and buttons at the same time erases all the values in historical storage.

Timer (self-triggering)

Press this button to set a 5-second time delay. or

Press and hold down this button until the desired time delay is reached (max. 60 seconds).

Once the key is released with the laser activated, the remaining seconds until measurement (e.g. 59, 58, 57...) are displayed in a countdown. The last 5 seconds are counted down with a beep. After the last beep the measu- rement is taken and the value is displayed.

)The timer can be used for all measurements.

Appendix

Message codes

All message codes are displayed with either or "Error". The following errors can be corrected:

Cause

Remedy

156Transverse tilt greater than 10° Hold the instrument without any transverse tilt

160

Main tilt direction, angle too

Measure angle up to max. ± 45°

 

high (> 45°)

 

162

The calibration has not been

Calibrate the device on an abso-

 

accomplished on a leveled

lute horizontal leveled surface.

 

surface and the calibration value

 

 

is respecitvely within an

 

 

ineligible area.

 

204

Calculation error

Repeat procedure

252

Temperature too high

Cool down instrument

253

Temperature too low

Warm up instrument

255

Receiver signal too weak,

Use target plate

 

measurement time too long,

 

 

distance > 100 m

 

256

Received signal too strong

Target too reflective (use target

 

 

plate)

257

Wrong measurement,

Darken target (measure in diffe-

 

background brightness too high

rent lighting conditions)

260

Laser beam interrupted

Repeat measurement

 

 

 

Error

Cause

Remedy

Error

Hardware error

Switch on/off the device several

 

 

times. If the symbol still appears,

 

 

then your instrument is defec-

 

 

tive. Please call your dealer for

 

 

assistance.

Appendix

14

Leica DISTO™ D5 LCA782204a en

Page 18
Image 18