Checking the accuracy of the vertical en plumbing:

(only Lino P3, Lino P5 and Lino L2P5)

Place the Lock switch 3 in the "Unlocked" ( ) position.

Checking the upper plumbing point:

B1

B2 max. 2 mm

 

1.5 m

1

2

 

A1

Checking the lower plumbing point:

 

A1

1

2

 

1.5 m

B1

B2 max. 2 mm

Set up the laser on its tripod or wall mount bracket near point A1 at a minimum distance of 1.5 m from point B1. The horizontal laser is aligned in direction 1. Mark the laser dots A1 and B1 with a pin.

Rotate the instrument by 180° so that it points in the opposite direction 2 to direction 1. Adjust the instru- ment so that the laser beam hits point A1 exactly. If point B2 is no further than 2 mm away from point B1, then the Leica Lino is within tolerance.

)Should your Leica Lino be outside of the spec- ified tolerance, please contact an authorised dealer- ship or Leica Geosystems.

Display notices

Falling below or exceeding the permissible temperature range:

The laser switches off and all symbols flash.

Outside of the self-levelling range:

The laser switches off and the symbol of the function used starts to flash.

Pendulum locked:

(only Lino L360, L2P5, L2+, and L2)

The laser beam is not levelled and the Lock symbol 7 lights up.

Operation

10

Leica Lino 757665g en

Page 11
Image 11
Leica L2P5, P3 manual Display notices