Thermostat Installation:

Note: Always Disconnect Power Before Performing The Thermostat Installation.

A 24 volt wall thermostat and 20 feet of 18-gage thermostat wire is included in the accessory package. It is recommended that the thermostat and thermostat wire be installed by an authorized Lennox Hearth Products dealer.

Installation Steps:

1.Unplug stove power cord from the wall outlet.

2.Locate the thermostat terminal block (see Figures 12 through 16).

3.Loosen the two terminal screws on the terminal block and remove the jumper.

4.Connect the two wires from your thermostat to the terminals (one per terminal). Ensure that the purple wires from the harness remain connected to the terminal block and tighten the terminal screws. Make sure the wires are firmly connected to the thermostat.

5.Plug in the stove and you are ready to operate with your thermostat!

Note: See Wiring Diagram on Page 32.

IMPORTANT: IF THE WALL THERMOSTAT PROVIDED IS NOT USED, THE JUMPER IS REQUIRED FOR THE STOVE TO OPERATE.

Leave jumper on, if thermostat is NOT used

Jumper

Remove jumper if Thermostat IS to be used

Terminal

Thermostat wires

and purple wires

Block

from wire harness

 

will connect to

 

these 2 terminals

Jumper

Figure 12 - Terminal Block - Type A

10

Leave jumper on, if thermostat is NOT used

Jumper

Remove jumper if Thermostat IS to be used

 

Thermostat wires

Terminal

and purple wires

from wire harness

Block

will connect to

 

 

these 2 terminals

Jumper

Figure 13 - Terminal Block - Type B

Terminal Block

Figure 14 - Terminal Block, Profile® 20FS-2

Model: ProÞle 30 FS-2

Terminal Block

Figure 15 - Terminal Block, Profile 30 FS-2

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Terminal Block

Figure 16 - Terminal Block, Profile 30 INS-2

VENTING REQUIREMENTS

It is recommended that only an authorized dealer install your pellet stove. The specified installation requirements must be followed to ensure conformity with both the safety listing of the appliance and local building codes. All clearances, installation instructions and precautions specified by the vent manufacturer must be followed.

Selecting a Location (Free-Standing Models)

Review the appliance clearance requirements before installing the venting system (see Page 6). Position the appliance far enough away from walls to allow adequate room for servicing. Choose the appliance location with the least amount of interference with the house framing, plumbing, wiring, etc.

Preferred Vent ConÞguration

For the best performance, we recommend a vent run design which runs vertically and terminates above the roof line. This design will allow natural draft to improve the flow of flue gases and will aid in combustion and stove performance.

Type of Pipe

This stove requires type “PL” vent pipe (pellet vent pipe, sometimes referred to as “L-Vent pellet vent”), listed to UL 641 or ULC S609. Connect the pellet vent pipe or the “tee” to the flue collar using a minimum of three screws and seal as specified in “Pipe / Liner Joint Requirements” on Page 11. Do not use class B gas chimney or single wall chimney as a substitute.