Thermostat Installation:
Note: Always Disconnect Power Before Performing The Thermostat Installation.
A 24 volt wall thermostat and 20 feet of
Installation Steps:
1.Unplug stove power cord from the wall outlet.
2.Locate the thermostat terminal block (see Figures 12 through 16).
3.Loosen the two terminal screws on the terminal block and remove the jumper.
4.Connect the two wires from your thermostat to the terminals (one per terminal). Ensure that the purple wires from the harness remain connected to the terminal block and tighten the terminal screws. Make sure the wires are firmly connected to the thermostat.
5.Plug in the stove and you are ready to operate with your thermostat!
Note: See Wiring Diagram on Page 32.
IMPORTANT: IF THE WALL THERMOSTAT PROVIDED IS NOT USED, THE JUMPER IS REQUIRED FOR THE STOVE TO OPERATE.
Leave jumper on, if thermostat is NOT used
Jumper
Remove jumper if Thermostat IS to be used
Terminal | Thermostat wires |
and purple wires | |
Block | from wire harness |
| will connect to |
| these 2 terminals |
Jumper
Figure 12 - Terminal Block - Type A
10
Leave jumper on, if thermostat is NOT used
Jumper
Remove jumper if Thermostat IS to be used
| Thermostat wires | |
Terminal | and purple wires | |
from wire harness | ||
Block | ||
will connect to | ||
| ||
| these 2 terminals |
Jumper
Figure 13 - Terminal Block - Type B
Terminal Block
Figure 14 - Terminal Block, Profile®
Model: ProÞle 30
Terminal Block
Figure 15 - Terminal Block, Profile 30
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Terminal Block
Figure 16 - Terminal Block, Profile 30
VENTING REQUIREMENTS
It is recommended that only an authorized dealer install your pellet stove. The specified installation requirements must be followed to ensure conformity with both the safety listing of the appliance and local building codes. All clearances, installation instructions and precautions specified by the vent manufacturer must be followed.
Selecting a Location
Review the appliance clearance requirements before installing the venting system (see Page 6). Position the appliance far enough away from walls to allow adequate room for servicing. Choose the appliance location with the least amount of interference with the house framing, plumbing, wiring, etc.
Preferred Vent ConÞguration
For the best performance, we recommend a vent run design which runs vertically and terminates above the roof line. This design will allow natural draft to improve the flow of flue gases and will aid in combustion and stove performance.
Type of Pipe
This stove requires type “PL” vent pipe (pellet vent pipe, sometimes referred to as