SPECIFICATIONS - PROFILE¨ 20 FS-2

 

 

 

 

 

 

 

22-3/8"

 

 

 

 

 

 

 

 

 

Cat. No. H0367

Model ProÞle 20 FS-2

Pellet Stove

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue Size

 

3Ó (76 mm Rear)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width, Overall

 

22-3/8Ó (568 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth, Overall

 

22-3/4Ó (578 mm)

28-5/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth, Overall w / 3Ó tee

28-1/2Ó (724 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

 

28-5/8Ó (727 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Floor to Rear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue Center

 

11-1/4Ó (286 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Facing back of unit,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-1/4Ó

6-1/2"

 

 

 

 

 

 

 

 

 

12"

 

 

 

outside edge of left side

 

 

 

 

 

 

 

 

 

 

 

 

8-¾Ó

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to center of rear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-1/2Ó (165 mm)

 

 

 

 

 

 

 

 

 

 

8-3/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ßue outlet center

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Floor to Rear

 

 

 

 

 

 

 

BACK VIEW

 

 

 

 

 

Outside Air Inlet

 

12Ó (305 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Facing back of Unit

 

 

 

 

 

 

 

 

28 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

w/clean-out tee

 

 

 

 

 

 

outside edge of right side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22 3/4"

 

 

 

 

 

 

 

 

 

 

to center of air inlet

 

8 3/8Ó (213 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Floor Protection

 

Front and Sides: 6Ó (152 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Requirements

 

Back: Up to 6Ó (152 mm) ￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Features

 

FastÞreSelf Igniter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall Thermostat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(wire included)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hopper Capacity

 

55 lbs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burn time

 

15 - 37 hours ￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse, Control Board

 

 

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 Amp, 250 volt, 3AG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse, Igniter

 

6 Amp, 125 volt ￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Input (BTUÕs per hour)

13,000 - 32,000 BTU / hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overall EfÞciency

 

75 - 81%

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Emissions

 

0.4 gr / hr (varies w/size and

 

 

 

 

SIDE VIEW

 

 

 

 

 

 

 

type of fuel) EPA exempt ￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping Weight

 

215 lbs.

 

Note: Dimensions shown are approximations only (+/- 1/4”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Room Air Blower

 

150 CFM; .8 Amps,

￿Non-combustible floor protection is required (see Floor Protection,

 

 

 

 

2175 rpm

 

Page 4). When installed at clearances less than 6”, the floor protector

 

 

 

 

 

is only required to extend to the wall.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exhaust Blower

 

95 CFM: 1.0 Amps,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3000 rpm

 

￿Fuel delivery and burn times will vary depending on size and type of fuel

 

 

Auger Motor

 

1.1 RPM; .4 Amps

used. Estimated heat input based on fuel value of 8400 BTU per lb.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

Nickel or Gold Trim Kits

￿Fuses are rated as fast blow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4Ó Quick Disconnect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Log Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

 

 

 

 

29