3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 6 - Blower Control Knob

Vintage™ 27 Blower Wiring Diagram

Blower Operation
The blower will come on when the stove is up to temperature and shut
off when the stove cools. The blower control knob must be turned “ON”
for the blower to operate (see Figure 6).
Blower Control knob - The highest blower speed is obtained by turning
the control knob clockwise until it clicks “ON.” Continue to rotate the knob
clockwise for a lower speed. To turn off, rotate the knob counterclockwise
until it clicks “OFF.”
WARNINGS
Once the new blower is properly installed, it must be
plugged directly into a properly grounded three-prong
receptacle, 120 VAC, 60 hz, single phase power supply.
Do not cut or remove the grounding prong from this plug.
Do not route power cord under or in front of appliance.
Ground supply (green) lead must be connected to the
wire attached to the green ground screw located on the
unit or blower assembly. Failure to do so will result
in a potential safety hazard. The appliance must be
electrically grounded in accordance with local codes
or, in the absence of local codes, the National Electri-
cal Code, ANSI/NFPA 70-latest edition. (In Canada, the
current CSA C22-1 Canadian Electrical Code).
Blower Snap Switch - N/O
BLOWER
Blower Speed Control
Speed Control
Wire (Red)
Snap Switch
Connection Wire
(Black)
Speed Control
Connection Wire (Black)
N/O - Normally Open (Contacts
Close When Stove Is hot)
Main Power Cord
Wire (Black)
Main Power Cord
Wire (White)
Ground Wire
(Green)
Main Power Cord
Wire (Black)
Speed Control Wire (Red)
Control knob
Figure 7 - Wiring Diagram
CAUTIONS
• Disconnect the plug from receptacle prior to servicing the
blower.
• Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
• Verify proper operation after servicing.
Blower
Control knob
Left Side of Stove