Step 5: REMOVE MATERIALS FROM FIRE- BOX - Remove the packaged materials from inside of the Þrebox and set aside (propane conversion kit, log support cartons, log set and embers).

Step 6: REMOVE CARDBOARD - Remove the cardboard packaging material from beneath the relief door and discard (see Figure 9).

Remove Cardboard

RELIEF DOOR

Figure 9

Step 7: INSTALL LP CONVERSION KIT (IF

NECESSARY) AND OPTIONAL ACCESSORIES

-Install the LP conversion kit and optional accessories per instructions provided with the kits (do not install an optional Þrescreen or brick liner kit at this point).

A.Optional accessories include a wall ther- mostat, blower kit, brick liner kit, warming shelves and a standard or deluxe remote control kits.

B.If a wall-mounted thermostat is selected, mount it in a convenient location on a wall near the stove. If the warming shelves are being installed, see Homeowners Manual for installation instructions.

C.Wirethethermostat withinthemillivoltcontrol circuitusinga maximum of 25feetof18 gage, 2 conductor wire. Caution: Do not connect the optional wall thermostat, gas control valve or

control wiring system of the unit to a 120 volt power supply (residential line voltage)

The gas valve is set in place and pre-wired at the factory on both models (see Figure 11).

SIT Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced, it must be replaced with Type AWM105°C – 18 GA. wire.

 

TH TP

TP

TH

Thermopile

* SWITCH

* ON/OFF SWITCH, OPTIONAL

Figure 10 THERMOSTAT OR REMOTE CONTROL RECEIVER

Wiring - Optional Forced Air Blower Kit: BK-CI (see Figure 11 for wiring diagram) - (An optional Þeld-providedoutletbox/J-Box may also be used). Install the blower kit according to the installation instructions provided with the kit.

Blower Wiring Diagram

Power Cord

Blower Assembly (Shown Rotated 90

BlowerDegrees CCW)

Mounting

Bracket

Black Black

White

White Black

Fan Disc

Rheostat

Figure 11

IMPORTANT: Ground supply wire must be connected to the green wire attached to the green ground screw. Failure to do so will result in a potential safety hazard. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70 - latest edition. In Canada, the current CSA C22-1 Canadian Electrical - latest edition.

WARNING: THE POWER CORD MUST BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG 120 VOLT, 60 HZ WALL RECEPTACLE. Do not cut or remove the grounding prong from this plug. Do

not route power cord under or in front of appliance.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Step 8: INSTALL LOWER ACCESS DOOR .

Install the lower access door by inserting the tabs on the door sides into the corresponding holes on the brackets on the stove bottom (see Figure 12 below)

Theloweraccess doorhingesopen to access Valve Controls

Lower Access

Door

Figure 12

Step 9: VENTING SYSTEM INSTALLATION

INSTALL VENTING COMPONENTS PER VENT MANUFACTURERS INSTRUCTIONS

The vent system may not service multiple appliances, and must never be connected to a ßue serving a solid fuel burning appliance.

CAUTION: Under no circumstances should these appliances be vented to other rooms or buildings. These appliances must only be vented to the outside. Vent terminations shall not be recessed into a wall or siding.

IMPORTANT: Do not exceed the maximum horizontal run allowed (see Figure 13 & 14).

Support Brackets - Install vent support brackets as speciÞed in the vent manufacturers instructions and the National Gas Fuel Code, USA - NFPA 54 / ANSI Z223.1, 7.6.5 Support ofGasVents.Gasventsshallbesupportedand spaced in accordance with their listings and the (vent) manufacturer instructions.

General Information: These instructions should be used as a guideline and do not supersede local codes in any way. Install vent according to local codes, these instructions, the current National Fuel Gas Code (NFPA 54 / ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 and -B149.2 in Canada.

These stoves are designed, tested and listed for operation and installation with, and only with, "Security Secure VentTM " or "Simpson Dura Vent" brand Components (co-axial DV pipe with 4" inner & 6 5/8" outer diameter). These approved vent system components are labeled for identiÞcation. DO NOT use any other manufacturer's vent components with these appliances.Thesestovesmustbeventeddirectly to the outside.