10

MAINTENANCE

(See Maintenance Schedule, Page 25)

Refer to the maintenance schedule for maintenance
tasks, procedures, periodicity and by whom they
should be performed. Always verify proper opera-
tion of the appliance after servicing.
Replacing Logs
If the logs become damaged by accident or
improper handling and need replacement, use
only the proper replacement logs from manu-
facturer (see Pages 13 and 14 for ordering
information).
Re-Install Embers and Logs
Carefully follow placement instructions on
Pages 12 through 14. All logs should fit
onto corresponding pins and/or log stop-
pers. This will ensure a proper flame and
safe combustion.
Inspect Wiring
Refer to wiring diagrams on Page 17.

CAUTION: Label all wires prior to discon-

nection when servicing controls. Wiring

errors can cause improper and dangerous

operation. Verify proper operation after

servicing.

ATTENTION: Au moment de l'entretien

des commandes, étiquetez tous les fils

avant de les débrancher. Des erreurs de

cáblage peuvent entraîner un fonction-

nement inadéquat et dangereux.

Inspect and clean all wire connections. Ensure
that there is no melting or damage. Inspection
should include:
• TerminalsattheValve
• OFF/ONSwitch
• (OptionalControlSwitch)WallThermostat,
Remote Control or Remote Wall Switch Kit
Inspect Burner Flame Appearance
Ensure that the burner flame appearance
resembles the flame shown in Figure 9 and
as described in Flame Appearance and Sooting
on Page 15. The Homeowner must contact
a qualified ser vice technician at once if any
abnormal condition is observed.
Small Area Paint Touch-up
Only use a factory supplied paint kit for touch-
ups. Paint is available at your local authorized
Lennox Hearth Products dealer. Never attempt
to paint a hot fireplace.
Do not attempt to repaint the appliance until
the finish is completely cured (see Burn-In
Period on Page 7). If the surface later becomes
stained or marred, it may be lightly sanded and
touched up with spray paint.

CAUTION: Wear gloves and safety

glasses for protection while doing

required maintenance.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adé-

quatement une fois l'entretien terminé.

Always turn off gas to the pilot (millivolt

appliances) before cleaning. Before re-

lighting, refer to the lighting instructions

in this manual. Instructions are also found

on a pull-out panel located in the control

compartment.

Inspect Venting System
The appliance and venting system should be
thoroughly inspected before initial use and
at least annually by a qualified service techni-
cian (inspection should include ensuring that
exhaust or intake passages are unobstructed
and vent components are properly assembled
and not damaged). Homeowner must contact
a qualified service technician at once if any
abnormal condition is observed.
If the venting system is disassembled for any
reason, a qualified service technician should
follow vent installation instructions for proper
reassembly and proper sealing of the venting
system components. However, more frequent
periodic inspections and cleanings should be
performed by the homeowner.
Cleaning Glass
(see Front Glass Enclosure Panel, Removal and
Installation on Page 11).
Note: Clean glass after first two weeks of opera-
tion (after Burn-In period is over) and then only
when necessary and when the fireplace is cool.
Wipe surface with a clean, dampened, soft cloth.
Follow with a dry, soft towel as desired. Take
care not to scratch the glass surface.
The viewing glass should be cleaned periodi-
cally to remove any build-up caused from the
following:

IMPORTANT: Do not use abrasive clean-

ers on glass. Never clean the glass when

it is hot.

• Duringstart-up,itisnormalforcondensa-
tion to form on the inside of the glass (this
condensation and fog will usually disappear
in a few minutes). The moisture can cause
lint, dust and other airborne particles to cling
to the glass surface.
• Initialcuringofthehightemperaturepaint
and burning off of lubricants used in the
manufacturing process may result in a film
on the glass.
• Awhitecoatingmayformontheglassasa
result of impurities and minerals in the fuel.
It is recommended that the glass be cleaned
two or three times during each heating season,
depending on the circumstances present. The
following cleaning solutions are approved for
use to clean glass:
•Non-ammoniabasedhouseholdcleaner
•50%-50%mixofwhitevinegarandwater
•Gasreplace/stoveglasscleaner
Inspect Glass Gasket - Visually inspect the
gasket on the backside of the glass enclosure
panels. The gasket surface must be clean, free
of irregularities and seated firmly.
Clean Control Compartment
Keep control compartment clean by vacuuming
or brushing at least twice a year. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding materials, etc. It is
important that control compartments, burners
and circulating air passageways of the appliance
be kept clean.
Clean Logs And Burner
Carefully remove the logs (use care when han-
dling the fiber logs, as they become quite fragile
after curing). Vacuum out any foreign matter
(lint, carbon, etc.) on the burner. Ensure the
burner ports are “open.” Remove any carbon
deposits from the under side of the logs using
a vacuum cleaner, or a soft bristled brush (i.e.
paint brush).
Note: Improper positioning of logs can create
carbon build-up and will alter the performance
of the appliance.
WARNING