GENERAL INFORMATION

 

This log placement guide has been prepared to present detailed log

 

placement illustrations and provide instruction to assist in the place-

 

ment of logs at the initial (new appliance) setup and after the annual

 

cleaning and inspection cycles. The information provided here is to

 

be used in conjunction with the Homeowner's Care and Operation In-

 

structions provided together with this document in the appliance lit-

 

erature packet. Please read the Homeowner's Care and Operation In-

 

structions completely before completing the procedures detailed in

Figure 1

this placement guide.

INITIAL INSTALLATION CONSIDERATIONS

If the logs are being installed for the first time, the following paragraphs apply:

DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.

Step 1. Remove the appliance front door.

Step 2. Remove the foamed log set from the interior of the firebox. Remove the logs from their packaging. Handle logs carefully to prevent breakage.

CERAMIC FLOOR PANELS, LOGS AND GLOWING EMBER PLACEMENT

Step 1. Install the Ceramic Floor Panels as shown in Figure 3 (for Direct Vent fireplaces only).

Note: This appliance is provided with enough Glowing Embers for several applications, do not feel compelled to use all that is in a new bag. For best glowing effect, replace the ember material annually. Replacement Glowing Embers are available (Catalog Number 88L53).

Step 2. Position the individual logs as shown in Figures 4A and 4B on pages 3 and 4. Logs should be placed in the order shown. All logs that have notches to fit over the grate tines should be positioned with these notches directly against the grate. Proper log placement is critical to encourage outstanding flame appearance and prevent sooting. When positioned properly as shown, logs will be positioned between flame peaks and will not impinge any flames.

Glowing Embers

Figure 2

Note: Do Not place Glowing Embers (Rockwool) over burner slots.

Step 3. Separate the Glowing Ember (Rockwool) into pieces about the size of a quarter Figure 1. Keep the pieces fluffed up, not matted. Distribute these pieces over the front surface of the burner, as shown in Figure 2. Do not use more than is necessary. When properly posi- tioned, the Glowing Embers will cover approximately 65% of the front burner and with no appreciable gaps or openings. Ensure that the main burner ports remain uncovered by the ember material.