LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE

FOR YOUR SAFETY, READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.This appliance has a pilot which must be lighted with a piezo igniter. When lighting the pilot, follow these instructions exactly.

B.BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire depart- ment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Access the lower control compartment.

3.Turn remote wall switch to “OFF.”

4.Verify main line shut-off valve is open.

5.Push in gas control knob slightly and turn clockwise to “OFF.”

PILOT

 

O

O N

 

 

 

 

TH

TH

PIEZO

 

it

 

 

 

 

 

SIT Millivolt

T

 

WO L

 

 

 

 

 

IGNITER

I

 

 

 

 

 

 

L

F FO

 

 

 

 

 

 

P

 

 

 

 

 

 

 

Gas Valve

 

 

H I

 

 

 

TP

TP

 

 

 

 

 

 

 

 

TPTH

TP/TH

 

 

 

 

 

 

 

 

 

 

 

IN

OUT

 

 

 

 

 

 

 

 

GAS CONTROL

- LO/HI +

 

 

 

 

 

 

 

 

 

 

KNOB

 

 

 

 

 

 

 

 

 

 

GAS CONTROL

 

 

PIEZO

 

 

 

 

 

KNOB

 

 

 

IGNITER

- LO/HI +

 

 

 

 

 

 

 

 

Honeywell Millivolt

 

 

 

 

 

 

 

 

 

Gas Valve

TP/TH

 

 

 

 

 

OI

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

L

 

TP

 

 

 

 

 

P

 

O

 

 

 

 

L

I

H

 

 

 

 

FFO

 

 

 

 

 

 

 

TO

 

 

 

 

TH

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.

7.Push in gas control knob slightly and turn counterclockwise

to “PILOT.”

8.Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark igniter (pushing the button) until pilot lights. Continue to hold the control knob in for about 1-1/2 minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If pilot will not stay lit after several tries,

turn the control knob to “OFF” and call

Millivolt Pilot

your service technician or gas supplier.

 

9.Turn gas control knob counterclockwise to “ON.”

10.Close lower control compartment.

Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.

TO TURN OFF GAS TO APPLIANCE

1.

Turn remote wall switch “OFF.” The pilot will remain lit for

4.

Depress gas control knob slightly and turn clockwise

 

normal service.

 

to “OFF.” Do not force.

2.

For complete shutdown, turn remote wall switch to “OFF.”

5.

Close lower control compartment.

 

 

3.Access the lower control compartment.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.