MAINTENANCE
Annually (Before the onset of the Burning Season)
Maintenance Task |
| Accomplishing Person |
| Procedure |
|
|
|
| |
Inspecting/Cleaning Burner, Logs |
| Qualified Service Technician | Inspect valve and ensure it is properly operating. Check piping | |
and Controls |
|
| for leaks. Vacuum the control compartment, fireplace logs and | |
|
|
| burner area. |
|
|
|
|
|
|
Check Flame Patterns and Flame |
| Qualified Service Technician | Refer to Figure 13 | on Page 7 and verify the flame pattern |
Height |
|
| and height displayed by the appliance conforms to the picture. | |
|
|
| Flames must not impinge on the logs. | |
|
|
|
|
|
Inspecting/Cleaning Pilot and Burner |
| Qualified Service Technician | Refer to Figure 13 | on Page 7 and Figure 25 on Page 11. |
|
|
| Remove any surface | |
|
|
| Wipe the pilot nozzles, ignitor/flame rod and hood. Ensure the | |
|
|
| pilot flame engulfs the flame sensor as shown. | |
|
|
|
| |
Checking Vent System |
| Qualified Service Technician | Inspect the vent system at the top and at the base (within the | |
|
|
| firebox) for signs of blockage or obstruction. Look for any signs | |
|
|
| of dislocation of the vent components. | |
|
|
|
| |
Appliance Checkout |
| Qualified Service Technician | Perform the appropriate appliance checkout procedure detailed | |
|
|
| in this manual. |
|
|
|
|
| |
Replacing Rockwool Ember Materials |
| Homeowner/Qualified Services Techni- | Remove old ember materials and vacuum the rockwool place- | |
|
| cian | ment area. Place new rockwool as described on Page 10 (see | |
|
|
| Figure 23). |
|
|
|
|
|
|
Periodically (After the Burning Season) |
|
|
| |
|
|
|
| |
Maintenance Task |
| Accomplishing Person |
| Procedure |
|
|
|
| |
Cleaning Firebox Interior |
| Homeowner | Carefully remove logs, rockwool and and vermiculite. Vacuum out | |
|
|
| interior of the firebox. Clean firebox walls and log grate. Replace | |
|
|
| logs, Rockwool and vermiculite as detailed in this manual. | |
|
|
|
| |
Check Flame Patterns and Flame |
| Homeowner | Refer to Figure 13 on Page 7 and verify the flame pattern and | |
Height |
|
| height displayed by the appliance conforms to the picture. Flames | |
|
|
| must not impinge on the logs. | |
|
|
|
| |
Checking Vent System |
| Homeowner | Inspect the vent system at the top and at the base (within the | |
|
|
| firebox) for signs of blockage or obstruction. Look for any signs | |
|
|
| of dislocation of the vent components. | |
|
|
|
| |
Cleaning Front Door Window |
| Homeowner | Clean as necessary following the directions provided in this | |
|
|
| manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE | |
|
|
| HOT. |
|
|
|
|
|
|
6 | NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. |