Direct-vent AND B-vent options

EliteSeries gas inserts are available in two venting configurations. Direct-vent models receive 100% of their combustion air from outside of the home for greater efficiency and are ideal for airtight homes. We also offer B-vent inserts that draw combustion air from inside the home so they require less chimney flue space for ducting. Both systems feature ceramic glass panels that seal the combustion area for efficiency and safe indoor air quality.

Minimum Fireplace Opening

MODEL

FRONT WIDTH (A)

HEIGHT (B)

DEPTH (C)

BACK WIDTH (D)

 

 

 

 

 

EDVI25

27"

19"

14-1/2"

23-1/4"

EBVI25

27"

19"

14-1/2"

23-1/4"

EDVI30

26-1/2"

22"

14"

22-1/2"

 

 

 

 

 

EBVI30

26-1/2"

21"

14"

22-1/2"

EDVI35

32-1/4"

25"

17"

25"

Typical Fireplace

Outside Exhaust

Outside Intake

Warm Air Out

Sealed

Combustion Area

Ceramic Glass

Ceramic Fiber

Log Set

Cool

 

Room Air In

Air Blower

Direct-vent

Draws combustion air from outside and returns combustion exhaust back to the outside of the house.

Outside Exhaust

B-vent

Warm Air Out

Sealed

Combustion Area

Ceramic Glass

Ceramic Fiber

Log Set

Cool

 

Room Air In

Air Blower

B-vent

Draws combustion air from inside the home and vents combustion exhaust to the outdoors.

C

Side View

Minimum Clearance To Combustibles

MODEL

ADJACENT WALL

INSERT TO MANTEL

FLOOR MINIMUM*

 

 

 

 

EDVI25

8" minimum

12" to 15-1/2" minimum**

0" to non-combustible

EBVI25

8" minimum

12" to 15-1/2" minimum**

0" to non-combustible

EDVI30

8" minimum

12" to 18" minimum**

0" to non-combustible

 

 

 

 

EBVI30

8" minimum

12" to 18" minimum**

0" to non-combustible

 

 

 

 

EDVI35

8" minimum

12" to 18" minimum**

0" to non-combustible

Specifications

MODEL

GAS

BTU/HR

ENERGUIDE

STEADY STATE*

 

 

 

 

 

EDVI25

NG

25,000

65%

86%

LP

25,000

66%

89%

 

EBVI25

NG

25,000

64%

79%

LP

25,000

68%

81%

 

EDVI30

NG

30,000

69%

87%

 

 

 

 

B

D

* Requires up to 16" hearth extension from fireplace face. If hearth is elevated 7" min.,

no hearth extension is required. Refer to owner’s manual.

** Minimum mantel height from top of louvers varies depending on mantel projection.

 

LP

28,000

70%

89%

 

 

 

 

 

EBVI30

NG

30,000

62%

83%

 

 

 

 

A

Front View

Please refer to owner’s manual.

 

LP

28,000

60%

82%

EDVI35

NG

35,000

66%

86%

LP

34,000

70%

88%

 

*Based on maximum vent configuration.

5