G43UF / Page 7
EXHAUST PIPE VENTING TABLE
1 Maximum Equivalent Vent Length − One or Two Pipe Applications
Altitude Vent Size
(diameter) G43UF−24B−045 G43UF−24B−070
G43UF−36B−070
G43UF−36C−090
G43UF−48C−090
2 G43UF−48C−110
2 G43UF−60C−110 3 G43UF−60D−135
()
ft. mft.mft.mft.mft.m
0 − 2000 ft.
(0 609 )
2 in. 110 34 70 21 50 15 30 9 n/a n/a
(0 − 609 m) 2−1/2 in. 135 41 135 41 100 31 70 21 n/a n/a
3 in. 160 49 160 49 125 38 125 38 4 125 4 38
4 in. 250 76 250 76 225 69 200 61 180 55
2001 − 4500 ft.
(610 1371 )
2 in. 110 34 70 21 50 15 20 6 n/a n/a
(610 − 1371 m) 2−1/2 in. 135 41 135 41 100 31 70 21 n/a n/a
3 in. 160 49 160 49 125 38 125 38 4 90 4 27
4 in. 250 76 250 76 225 69 200 61 180 55
4501 − 7500 ft.
(1372 2286 )
2 in. 110 34 70 21 30 9 n/a n/a n/a n/a
(1372 − 2286 m) 2−1/2 in. 135 41 135 41 100 31 70 21 n/a n/a
3 in. 160 49 160 49 125 38 125 38 4 90 4 27
4 in. 250 76 250 76 225 69 200 61 180 55
7501 − 10,000 ft.
(2287 3048 )
2 in. 110 34 70 21 n/a n/a n/a n/a n/a n/a
,
(2287 − 3048 m) 2−1/2 in. 135 41 135 41 100 31 70 21 n/a n/a
3 in. 160 49 160 49 125 38 125 38 4 90 4 27
4 in. 250 76 250 76 225 69 200 61 180 55
NOTE − Minimum Equivalent Vent Pipe length is 15 feet (4.6 m).
1 Maximum Equivalent Vent Length" permitted is defined as Total Length (linear feet) of vent pipe, plus equivalent length (ft.) of fittings, plus equivalent length (ft.) of termination".
2 110 models must have the supplied 90° street ell installed directly into the unit flue collar. The street ell must be included in the elbow count.
3 135 models must have 3 in. to 2 in. reducing elbow (supplied) installed directly into the flue collar. Reducing ell must be included in elbow count.
4 90 elbows must be limited to 3 in. sweep type elbows.
VENTING NOTES  One 90elbow is equivalent to 5 feet (1.5 m) of straight vent pipe.
Two 45 elbows are equal to one 90 elbow.
One 45 elbow is equivalent to 2.5 feet (.75 m) of straight vent pipe.
Wall and roof termination (non−concentric) exhaust pipe must terminate with reducer to improve exhaust velocity away from intake piping.
045 and 070 − 2, 2−1/2, 3 or 4 in. − terminate with 1−1/2 in. pipe
090 − 2, 2−1/2, 3 or 4 in. − terminate with 2 in. pipe
110 − 2, 2−1/2, 3 or 4 in. − terminate with 2 in. pipe
135 − 3 or 4 in. − terminate with 2 in. pipe
TERMINATION KITS − EQUIVALENT VENT LENGTHS
Vent Pipe Equivalent Length − ft. (m)
Heat
Vent Pipe
Diameter
Concentric
Kits
Close Couple
Kits
Wall Ring
Kit
Outdoor Exhaust
Accelerator
(Diameter X Length)
Size 1−1/2 in.
(38 mm)
2 in.
(51 mm)
3 in.
(76 mm)
2 in.
(51 mm)
3 in.
(76 mm)
2 in.
(51 mm)
1−1/2 x 12 in.
(38 x 305 mm)
2 x 12 in.
(51 x 305 mm)
in. mm 71M80 69M29 60L46 22G44
30G28 (WTK)
44J40
81J20 (WTK) 15F74 − − − − − −
2 51 12 (3.6) not allowed not allowed 4 (1.2) 1 4 (1.2) 4 (1.2) 4 (1.2) not allowed
2−1/2 64 15 (4.6) not allowed not allowed 5 (1.5) 1 5 (1.5) 5 (1.5) 5 (1.5) not allowed
−045 376 21 (6.4) not allowed not allowed 7 (2.1) 1 7 (2.1) 7 (2.1) 7 (2.1) not allowed
4 102 42 (12.8) not allowed not allowed 14 (4.3) 1 14 (4.3) 14 (4.3) 14 (4.3) not allowed
2 51 12 (3.6) not allowed not allowed 4 (1.2) 1 4 (1.2) 4 (1.2) 4 (1.2) not allowed
2−1/2 64 15 (4.6) not allowed not allowed 5 (1.5) 1 5 (1.5) 5 (1.5) 5 (1.5) not allowed
−070 376 24 (7.3) not allowed not allowed 8 (2.4) 1 8 (2.4) 8 (2.4) 8 (2.4) not allowed
4 102 42 (12.8) not allowed not allowed 14 (4.3) 1 14 (4.3) 14 (4.3) 14 (4.3) not allowed
2 51 not allowed 3 (1) 3 (1) not allowed 1 (0.3) 2 1 (0.3) not allowed 1 (0.3)
2−1/2 64 not allowed 6 (1.8) 6 (1.8) not allowed 2 (0.6) 2 2 (0.6) not allowed 2 (0.6)
−090 376 not allowed 6 (1.8) 6 (1.8) not allowed 2 (0.6) 2 2 (0.6) not allowed 2 (0.6)
4 102 not allowed 12 (3.7) 12 (3.7) not allowed 4 (1.2) 2 4 (1.2) not allowed 4 (1.2)
2 51 not allowed 3 (1) 3 (1) not allowed 1 (0.3) 2 1 (0.3) not allowed 1 (0.3)
2−1/2 64 not allowed 6 (1.8) 6 (1.8) not allowed 2 (0.6) 3 2 (0.6) not allowed 2 (0.6)
−110 376 not allowed 6 (1.8) 6 (1.8) not allowed 2 (0.6) 3 2 (0.6) not allowed 2 (0.6)
4 102 not allowed 12 (3.7) 12 (3.7) not allowed 4 (1.2) 3 4 (1.2) not allowed 4 (1.2)
3 76 not allowed not allowed 15 (4.6) not allowed 6 (1.8) 3 6 (1.8) not allowed 6 (1.8)
−135 4 102 not allowed not allowed 25 (7.6) not allowed 10 (3.0) 3 10 (3.0) not allowed 10 (3.0)
1Requires field provided 1−1/2 in. (38 mm) outdoor exhaust accelerator.
2Requires field provided 2 in. (51 mm) outdoor exhaust accelerator.
3For use only in non−direct vent applications, when snow riser is not required. Requires field provided 2 in. (51 mm) outdoor exhaust accelerator.