Filters

This unit is not equipped with a filter or rack. A field-pro- vided, high-velocity filter is required to ensure proper unit operation.

A filter must be in place any time the unit is operating.

Seasonal Inspections

A qualified service technician should inspect the complete system each season (heating and cooling). The following maintenance procedures should only be conducted by a qualified service technician. Do not attempt to service the unit in any way.

Venting System

WARNING

Asphyxiation Hazard

The exhaust vent for this furnace must be securely connected to the furnace flue collar at all times.

For your safety and to fulfill the terms of the limited warranty, a qualified service technician must annual4 ly inspect this furnace and its vent system.

Annually (before heating season) inspect furnace venting system, vent cap, heat exchanger and burners for corro- sion, deterioration, or deposits of debris. Remove any ob- structions.

Inspect thefurnace venting system to make sure it is in place, physically sound and without holes, corrosion, or blockage. The vent connector must be correctly posi- tioned and sloped upward. The vent connector must be physically sound, without holes or excessive corrosion.

Inspect the furnace return air duct connection. The duct must be sealed to the furnace and it must terminate outside the space containing the furnace.

Inspect the physical support of the furnace to guarantee that it is sound. The support must not sag and must not have cracks or gaps around the base of the furnace. There must be a seal between the furnace base and the support. During a seasonal check, the service technician will in- spect the indoor blower and the burner flames along with the venting system.

Blower

Check blower wheel for any debris and clean it, if neces- sary. The blower motor is pre-lubricated for extended bear- ing life. No further lubrication is needed.

Burner Flame

CAUTION

To ensure proper operation, a qualified technician should annually check the burner flame.

Service Reminder

Call your Lennox service technician if the unit will not oper- ate. Before calling, always check the following to be sure service is required.

1 - Check that electrical disconnect switches are ON.

2 - Check room thermostat for proper setting.

3 - Replace any blown fuses or reset circuit breakers. 4 - Gas valve should be ON.

5 - Air filter should not be plugged, which wil limit air flow. 6 - Is gas turned on at meter?

7 - Is manual main shut-off valve open?

Record the model and serial number of the furnace. These numbers are on the unit nameplate, which is located below the burners.

Serial Number ________________________________

Model Number ________________________________

Safety Precautions

If you discover any of the following, shut down your unit and contact a Lennox dealer for an inspection by a qualified technician.

D If you repeatedly hear any new or unfamiliar sounds while your unit is operating, there may be a problem. For example, poorly performing burners can produce unfa- miliar noises.

DIf you smell any unusual odors, your unit may be operat- ing improperly. For example, units can give off unfamil- iar odors if components are required to operate in ab- normal conditions.

DLook for visible signs of a malfunctioning unit. Examples include unusual amounts of condensate on windows in- side your house, visibly burnt components or unusual dirt or rust accumulations on the vent pipe or in the unit.

DIf you experience headache, nausea, fatigue, or dizzi- ness, the cause could be exposure to carbon monoxide gas. This is often misdiagnosed as the flu because symptoms are similar. If you suffer from flu-like symp- toms that are exaggerated at home, but seem to sub- side while you are away from the house, exposure to carbon monoxide could be the cause.

Your vigilance may pay off in early detection of a problem before either personal injury or property damage occurs. Do not hesitate to contact a qualified service technician as an investment in your well being.

Page 5

Page 5
Image 5
Lennox Hearth G60UHV(X) manual Filters, Seasonal Inspections, Service Reminder, Safety Precautions

G60UHV(X) specifications

The Lennox Hearth G60UHV(X) is a sophisticated and efficient gas fireplace insert that combines modern design with advanced technology, creating an impressive heating solution for any home. This unit stands out with its unique blend of aesthetics and functionality, making it an ideal choice for those looking to enhance the ambiance of their living spaces while also improving energy efficiency.

One of the key features of the G60UHV(X) is its remarkable heat output. With a maximum input of 60,000 BTUs, it is capable of heating large areas effectively, ensuring that you remain comfortable even during the coldest months. This fireplace insert is designed to provide a robust and consistent warmth that can compete with traditional heating systems, all while being more energy-efficient.

The G60UHV(X) utilizes Lennox’s innovative technology that enhances its performance. The unit is equipped with an advanced control system that allows users to adjust flame height and heat output to suit their preferences. This level of control ensures that homeowners can create the perfect atmosphere for any occasion, whether it's a cozy family gathering or a quiet night in.

Another notable characteristic is the G60UHV(X)’s realistic flame appearance. Thanks to its advanced燃料 technology, the fireplace produces rich, lifelike flames, creating an inviting and warm atmosphere. The use of hand-painted ceramic logs and high-quality glass media enhances the visual appeal, adding to the overall aesthetic of the insert.

Energy efficiency is at the forefront of the G60UHV(X)’s design. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, this fireplace insert minimizes energy consumption while maximizing warmth. This not only helps reduce utility bills but also contributes to a smaller carbon footprint, making it an environmentally friendly choice for heating your home.

The G60UHV(X) also features a user-friendly remote control option, allowing homeowners to adjust settings from the comfort of their seating area. The fireplace insert can be operated easily, making it a convenient option for individuals of all ages.

Durability is a hallmark of the Lennox brand. The G60UHV(X) is constructed from high-quality materials designed to withstand the test of time, ensuring that your investment remains functional and aesthetically pleasing for many years.

In summary, the Lennox Hearth G60UHV(X) stands out as an exceptional fireplace insert that seamlessly blends style, efficiency, and technology. With its powerful heating capability, realistic flame presentation, high-energy efficiency, and user-friendly features, it is a perfect addition to any home looking to upgrade its heating solutions.