HEARTH PRODUCTS KITS AND ACCESSORIES
P/N
ELDV Power Vent Adapter kit
INSTALLATION INSTRUCTIONS FOR The ELDV-PVAK (H7407)
Fireplace adapter kits (For
Fireplace | Kit Catalog | Kit Contents | ||
Model | Number | |||
|
| |||
|
| 5/8” Restrictor | Rear Log Bracket | |
ELDV | H7407 |
|
| |
|
| |||
|
|
| ||
|
|
| 1” Restrictor | |
Table 1 |
|
|
|
KIT CONTENTS
Log Support Bracket - 1 each, Restrictor 5/8” - 1 each, Restrictor 1” - 1 each
TOOLS NEEDED - 5/16” Nut Driver
GENERAL INFORMATION
This kit provides components that are designed to adapt any size ELDV fireplace to be used with the Lennox
ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND OPERATION MANUAL PROVIDED WITH THE APPLIANCE APPLY TO THESE INSTRUCTIONS.
Installation Instructions
Step 1. Remove the glass door per instructions in the ELDV Care and Operation Instructions Manual.
Step 2. Using a 5/16” nut driver, remove and discard the rear log sup- port bracket per instructions in Figure 1 and using the same screws, install the rear log support bracket provided with this kit. Orient as shown in Figure 1.
Step 3. Refer to Figure 2 and remove two screws securing the down- draft baffle. Remove and retain the
Step 4. Remove two screws securing the restrictor base plate and remove the restrictor assembly from the fireplace vent outlet.
Step 5. Remove two screws securing the restrictor body to the base plate. Discard the restrictor body.
Rear Log Support
Remove the 2 screws indicated by arrows
Figure 1 - Log Support Bracket
Vent Run Parameters
Any Vent Run With A Vertical Height | Use 5/8” Restrictor |
Greater Than 30 Feet | Provided With This Kit |
|
|
Any Vent Run With A Vertical Height | Use 1” Restrictor |
Less Than 30 Feet | Provided With This Kit |
|
|
Note: See Power Vent Kit manual for maximum and minimum vent run parameters.
Table 2
| restrictor Body |
Down Draft Baffle | restrictor Base Plate |
Figure 2 - Removing Baffle And Base Plate |
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.