NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
4
WARNING
Disposal of Ashes: Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dis-persed, they should be retained in the closed container until all cinders have thoroughly cooled.

CHIMNEY MAINTENANCE

Regular chimney inspection and maintenance
combined with proper operation will help pre-
vent chimney fires. Keep your chimney clean.
Do not allow more than a 1/16" (1.6mm) build-up
of creosote in your chimney. The amount of
creosote will depend on variables such as fre-
quency of use and type of fire. We recommend
that you follow the instructions below:
1. Initially, inspect the chimney system weekly.
By doing this, you will learn how often it will
be necessary to clean your chimney.
2. Have your chimney cleaned by a qualified
chimney sweep. Chimney maintenance
should only be conducted by a qualified
technical or chimney sweep company.
3. Do not expect chemical cleaners to keep
your chimney clean.
The raincap can be removed for inspection
and/or cleaning of the chimney. Unscrew the
braces which attach the raincap to the chimney.
Using gloves, firmly grip the upper portion of
the rain cap. Turn the cap and lift it off the
chimney.

CHIMNEY FIRES

If you are having a chimney fire, follow these
steps:
1. Close the glass doors and the air inlet.
2. Close the chimney outside air register.
3. Alert your family of the possible danger.
4. If you require assistance, alert your fire
department.
5. If possible, use a dry chemical fire extin-
guisher, baking soda or sand to control
the fire. Do not use water as it may cause
dangerous steam explosions.
6. Watch for smouldering or fire on combustibles
next to the fireplace and chimney. Check outside
to ensure that sparks and hot embers coming out
of the chimney are not igniting the roof.
7. Do not use the fireplace again until your
chimney and fireplace have been inspected by
a qualified chimney sweep or a fire department
inspector.

Door Frame Care

Use a glass cleaner and a soft cloth to polish
the frame. Do not use abrasives such as steel
wool or steel pads for they may scratch the
door frame finish.

Doors Adjustment

Glass doors may lose their adjustment during
transportation or installation of the fireplace.
A wrong adjustment may cause a loss in
combustion’s efficiency and control. The glass
doors must be parallel, at the same height and
must almost touch each other when closed.
Maximum spacing between the doors is one
sixteenth of an inch (1/16’’).
The glass doors can be adjusted by loosening
the three (3) screws of the hinges’ supports
(see fastening screws in Figure 1). If a minor
angular adjustment is needed, you may loosen
only two (2) of the three (3) screws using the
other as a pivot point.

GLASS CARE

Glass Replacement

The glass used for the ME43 fireplace doors is
a high temperature ceramic glass. If the glass
breaks, it must be replaced with a ceramic glass
such as Neoceram. Tempered or ordinary glass
will not withstand the high temperatures of the
ME43 fireplace. Replacement glass should be
purchased from your local LHP dealer.
DO
NOT OPERATE THE UNIT WITH CRACKED OR
BROKEN GLASS.
To remove the glass panel,
unscrew the frame screws, remove the interior
frame and the glass panel.

Glass Cleaning

The ME43 fireplace is designed to keep the
glass clean under normal operating condi-
tions. To clean the glass there are a number of
specially designed cleaners. Your authorized
LHP Dealer can recommend a suitable cleaner.
Regular household glass cleaners will not clean
creosote.
Do not use abrasives such as steel
pads, steel wool or oven cleaner as they will
scratch the glass.
DO NOT USE CHEMICAL GLASS CLEANERS
ON PAINTED SURFACES AS IT MAY CAUSE
THE PAINT TO PEEL.
CAUTION : DO NOT ALLOW WINDOW CLEANER
TO GET IN CONTACT WITH DOOR GASKET OR
PAINT ON FACADE OR DOOR. ONCE CLOSED,
CONTACT OF GLASS CLEANER WITH THE
FIREPLACE FACADE CAN PROVOKE PAINT
PEELING OFF.
Figure 1

Disposing Of Ashes

Remove ashes only when the fire is out and
the ashes are cold (24 to 48 hours after the
fire is out).
Do not leave the ashes in the house as they give
off carbon monoxide and other toxic gases.
Fastening
Screws
Interior Frame
Frame
Screws