NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Gas Flex Line
Gas Shut-Off
Valve Valve Piezo Spring Door
Latch
Lower Control
Compartment
LENNOX HEARTH PRODUCTS • MERIT® SERIES DIRECT-VENT GAS FIREPLACES • MODELS MLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS

Figure 41

Step 6. CONNECTING GAS LINE

All codes require a shut-off valve mounted
in the supply line. The orientation of the
shut-off valve should face the front. Figure
40 illustrates two methods for connecting the
gas supply. A Sediment Trap is recommended
to prevent moisture and debris in gas line from
damaging the valve.
The flex-line method is acceptable in the U.S.A.
where local codes permit, however, Canadian
requirements vary depending on locality. Instal-
lation must be in compliance with local codes.
These appliances are equipped with a gas
flex-line for use in connecting the unit to the
gas line. See Figure 40 for flex-line descrip-
tion. The flex-line is rated for both natural and
propane gas. A manual shut off valve is also
provided with the flex-line.
The gas control valve is located in the lower
control compartment.
Access the valve compartment by removing the
lower control compartment panel (see Figure
41) by lifting and pulling the panel forward.
The panel is mounted on supporting tabs at
the extreme right and left hand sides. Engage
the tabs into the reliefs in the panel.
The millivolt and electronic control valve has a
3/8" (10 mm) NPT thread inlet port.
Secure all joints tightly using appropriate
tools and sealing compounds (ensure propane
resistant compounds are used in propane ap-
plications). It is recommended to seal around
the gas line to prevent cold air leakage.
Gas line connection may be performed largely
outside of the confines of the control compart-
ment and without having to enter the firebox
behind the glass. Proceed as follows:
Acquire the shut-off valve and gas lex line and
pull the assembly forward out of the compart-
ment. Separate the shut-off valve from the gas
flex-line. Determine the length of pipe needed
to route the gas line from the last fitting (shown
in Figure 15 on Page 11) to a point within the
control compartment that will allow the shut-
off valve to be easily attached by hand to the
gas flex-line.
Using pipe-dressing materials appropriate for
the gas type, securely affix the shut-off valve
to this determined pipe length at a convenient
location outside of the appliance lower control
compartment.
GasValve

3/8" NPT x

Flare Fitting

3/8" Flex Tubing

3/8" Nipple

3/8" Union

3/8" Close

Nipple 3/8" Shut-off Valve

1/2" x 3/8"

Reducer

Gas

Stub

1/2" x 3/8" Flare

Shut-off Valve

Gas Solid Line ConnectorGas Flex Line Connector

*Sediment

Trap

3"
Min
Note: The gas supply line
must be installed in accor-
dance with building codes
by a qualified installer
approved and/or licensed
as required by the locality.
In the Commonwealth of
Massachusetts, installation
must be performed by a
licensed plumber or gas
fitter.

Figure 40

GAS CONNECTION
Length Of Pipe With
Attached Shut-Off Valve

Figure 42

Refer to Figure 42 and insert the last length
of gas pipe with its attached shut-off valve
into the lower control compartment, and pass
it through the gas line access hole on the left
side of the appliance outer wrapper. Using ap-
propriate materials for the gas type, thread the
last length of pipe into the end of the gas vent
run and tighten in place using a pipe wrench
external to the appliance between the appliance
outer wrapper and the framing.
Important: Turn the last piece of gas pipe in
the last fitting until the shut-off valve is posi-
tioned in a way that allows the shut-off valve
handle to be accessed in the lower control
compartment, easily operated throughout its
full range of motion.
Bring the flex-line to the shutoff valve by hand
and align the flare fittings. Tighten the fittings
by hand, and then use wrench to tighten com-
pletely, 1/4 turn at a time.