CHIMNEY INSTALLATION INSTRUCTIONS
1.Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 22). Use a plumb bob to line up the center of the holes. The sizes are indicated in Table 2 for the floor and ceiling holes and Table 3 (Page 15) for the roof holes.
CHIMNEY MODEL | SQUARE HOLE | |
| SIZE OPENING | |
|
| |
Secure Temp™ S2100+ |
| |
Nova Temp™ HT6000+ | 15 in (380 mm) | |
Secure Temp GX |
| |
ACBI: Ceiling | 15 in (380 mm) | |
(1” clearance) | ||
17 in (432 mm) | ||
Wall | ||
| ||
|
|
Note: See Table 3 for Sloped Roof Framing Table 2 - Flat Roof Framing
S2100 / HT6000+ | ACBI |
Solid Packed Pipe | Air Cooled Pipe |
Attic Radiation Shield |
|
Attic Radiation
Shield
| Firestop | Radiation Shield | |
Figure 23a | Figure 23b | ||
|
Figure 22 - Roof Framing
From below, install a firestop in each ceiling/floor separation through which the chimney will pass. At the attic level, install an attic radiation shield from above (Figures 23a & 23b).
2. For Secure Temp S2100+ / Nova Temp |
HT6000+ / Secure TempGX chimneys, place |
the first chimney length on the fireplace. |
To lock it in place, turn 1/4 of a turn clock- |
wise. With the ACBI chimney, you must |
use a starter section before installing the |
first chimney length (Figure 24). Continue |
installing chimney lengths making sure to |
lock each length in place. |
3. Every time the chimney passes through a ceil- |
ing or a wall, install the appropriate firestop. |
When you reach the desired height, install the |
roof support (Refer to instructions included |
with the support). For an ACBI chimney use |
an universal support AC10SU. |
4. Put the roof flashing in place and seal the |
joint between the roof and the flashing |
with roofing pitch (see Figures 25 & 26). |
For sloping roofs, place the flashing under |
the upper shingles and on top of the lower |
shingles. Nail the flashing to the roof, using |
roofing nails. |
5. Place the storm collar over the flashing, and |
tighten it with the bolt supplied. Finally, seal |
CHIMNEY INSTALLATION
MODEL ACBI
Optional Chimney
Outside Air Intake
Outside Combustion
Air Kit
Rain Cap
Collar
Flashing
Attic Radiation
Shield
Firestop
Universal Support
ACBI Starter Section
ACBI7SB or ACBI7SB30
Note: Outside air kits must be installed for both fireplace and ACBI chimney.
the joint between the storm collar and the |
chimney, using silicone caulking. |
6. Install the chimney cap. |
14
Figure 24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.