To light the burner, refer to the lighting instructions on page 14 and 15. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame sensor as shown in Figure 10
ELECTRONICProper Flame | 3/8 To 1/2 Inch | |
(9 mm to 13 mm) | ||
Adjustment | ||
| ||
Pilot |
| |
Nozzle | Ground | |
| ||
| Electrode | |
| Flame Rod | |
| Hot Surface | |
| Igniter |
Figure 10
With proper care and maintenance, your appliance will provide many years of enjoyment. If you should experience any problem, first refer to the trouble shooting guide in this manual. If problem persists, contact your Lennox distributor.
WIRING DIAGRAMSWiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within
1.If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.
2.120V, 60Hz – Less than 3 amps.
**ON/OFF Switch (Integral | **Leave the ON/OFF switch, which is integral | |||
with Gas Valve) | with the gas valve, in the ON position. | |||
| Gas Valve | PILOT |
|
|
|
|
|
| |
| IGNITER | ASSEMBLY |
|
|
BK |
|
|
| |
| R | Green |
|
|
| BL | White | Ground - Green | |
|
|
|
| Neutral - White |
| OPT |
| Black | 120 VAC - Black |
|
|
| ||
| BLOWER |
|
| Junction Box |
| Tab Intact |
|
|
|
|
|
| Tab |
|
|
|
| Broken |
|
|
|
| Red | Optional |
| Green |
|
| |
| Neutral | Hot | Accessory | |
| Ground | Side of | Side of | Switch |
| Screw | Receptacle | Receptacle |
|
W
BTransf.
| G | 120 V. |
|
| |
BL |
| 24 V |
|
| |
|
| R |
W
BK
OPTIONAL
OR OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE RECEIVER
*Blower speed control switch is provided in FBK200 blower kit.
Factory Wired | Field Wired |
Schematic Representation Only
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
1.If any of the original wire as supplied must be replaced,
1.it must be replaced with Type AWM 105° C – 18 GA. wire.
2.120V, 60Hz – Less than 3 amps.
*Leave the ON/OFF switch, which is integral
*ON/OFF Switch (Integral with the gas valve, in the ON position. with Gas Valve)
|
| Gas Valve |
| PILOT | Ground - Green | ||
|
|
|
|
|
| ||
|
|
|
|
|
| ASSEMBLY | |
|
|
| IGNITER |
| Neutral - White | ||
BK |
|
|
| 120 VAC - Black | |||
|
|
|
|
|
Optional
R
BL | Module | Green | White |
|
|
|
|
| |
OPT |
|
| Black |
|
BLOWER |
|
|
| Junction Box |
| Tab Intact |
| Tab |
|
|
|
|
| |
|
|
| Broken |
|
| Green |
| Red | Optional |
|
|
| ||
| Neutral | Hot | Accessory | |
| Ground | |||
| Screw | Side of | Side of | Switch |
|
| Receptacle | Receptacle |
|
W
BTransf.
G | 120 V. |
BL | 24 V |
| |
| R |
WH
BK
OPTIONAL
OR OPTIONAL REMOTE RECEIVER
Factory Wired | Field Wired |
Schematic Representation Only
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION.
Millivolt Wiring DiagramIf any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.
TP | TH TP |
| TH |
Thermopile
A complete parts list is found at the end of this manual. Use only parts supplied from the manufacturer.
Normally, all parts should be ordered through your Lennox distributor or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:If you encounter any problems or have any questions concerning the installation or application of this system, please contact your dis- tributor, or Lennox directly:
LENNOX HEARTH PRODUCTS1110 West Taft Avenue • Orange, CA 92865Field Wired
Factory Wired
*OPTIONAL
SWITCH OR OPTIONAL THERMOSTAT
*Turn the
Schematic Representation Only
WARRANTYYour gas appliance is covered by a limited twenty year warranty. You will find a copy of the warranty accompanying this manual. Please read the warranty to be familiar with its coverage.
8
We recommend that you record the following important information about your fireplace. Please contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox dealer, please call
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.